A quantum accounting and detective quantum efficiency analysis for video-based portal imaging

被引:56
作者
Bissonnette, JP
Cunningham, IA
Jaffray, DA
Fenster, A
Munro, P
机构
[1] LONDON REG CANC CTR,LONDON,ON N6A 4L6,CANADA
[2] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON,ON N6A 5C1,CANADA
[3] JOHN P ROBARTS RES INST,IMAGING RES LABS,LONDON,ON N6A 5K8,CANADA
[4] VICTORIA HOSP,DEPT DIAGNOST RADIOL,LONDON,ON N6A 4G5,CANADA
[5] UNIV WESTERN ONTARIO,DEPT RADIOL & NUCL MED,LONDON,ON N6A 5C1,CANADA
[6] WILLIAM BEAUMONT HOSP,DEPT RADIAT ONCOL,ROYAL OAK,MI 48073
[7] UNIV WESTERN ONTARIO,DEPT ONCOL,LONDON,ON N6A 5C1,CANADA
[8] UNIV WESTERN ONTARIO,DEPT PHYS,LONDON,ON N6A 5C1,CANADA
关键词
quantum accounting diagram (QAD); detective quantum efficiency (DQE); portal imaging;
D O I
10.1118/1.598009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The quality of images generated with radiographic imaging systems can be degraded if an inadequate number of secondary quanta are used at any stage before production of the final image. A theoretical technique known as a ''quantum accounting diagram'' (QAD) analysis has been developed recently to predict the detective quantum efficiency (DQE) of an imaging system as a function of spatial frequency based on an analysis of the propagation of quanta. It is used to determine the ''quantum sink'' stage(s) (stages which degrade the DQE of an imaging system due to quantum noise caused by a finite number of quanta), and to suggest design improvements to maximize image quality. We have used this QAD analysis to evaluate a video-based portal imaging system to determine where changes in design will have the most benefit. The system consists of a thick phosphor layer bonded to a I mm thick copper plate which is viewed by a T.V. camera. The imaging system has been modeled as ten cascaded stages, including: (i) conversion of x-ray quanta to light quanta; iii) collection of light by a lens; (iii) detection of light quanta by a T.V. camera; (iv) the various blurring processes involved with each component of the imaging system; and, (v) addition of noise from the T.V. camera. The theoretical DQE obtained with the QAD analysis is in excellent agreement with the experimental DQE determined from previously published data. It is shown that the DQE is degraded at low spatial frequencies (<0.25 cycles/mm) by quantum sinks both in the number of detected x rays and the number of detected optical quanta. At higher spatial frequencies, the optical quantum sink becomes the limiting factor in image quality. The secondary quantum sinks can be prevented, up to a spatial frequency of 0.5 cycles/mm, by increasing the overall system gain by a factor of 9 or more, or by improving the modulation transfer function (MTF) of components in the optical chain. (C) 1997 American Association of Physicists in Medicine.
引用
收藏
页码:815 / 826
页数:12
相关论文
共 34 条
  • [21] Analysis of signal propagation in optically coupled detectors for digital mammography .2. Lens and fibre optics
    Maidment, ADA
    Yaffe, MJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (03) : 475 - 493
  • [22] CALCULATION OF WATER AIR STOPPING-POWER RATIOS USING EGS4 WITH EXPLICIT TREATMENT OF ELECTRON-POSITRON DIFFERENCES
    MALAMUT, C
    ROGERS, DWO
    BIELAJEW, AF
    [J]. MEDICAL PHYSICS, 1991, 18 (06) : 1222 - 1228
  • [23] A DIGITAL FLUOROSCOPIC IMAGING DEVICE FOR RADIOTHERAPY LOCALIZATION
    MUNRO, P
    RAWLINSON, JA
    FENSTER, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03): : 641 - 649
  • [24] THERAPY IMAGING - A SIGNAL-TO-NOISE ANALYSIS OF METAL PLATE FILM DETECTORS
    MUNRO, P
    RAWLINSON, JA
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1987, 14 (06) : 975 - 984
  • [25] THERAPY IMAGING - A SIGNAL-TO-NOISE ANALYSIS OF A FLUOROSCOPIC IMAGING-SYSTEM FOR RADIOTHERAPY LOCALIZATION
    MUNRO, P
    RAWLINSON, JA
    FENSTER, A
    [J]. MEDICAL PHYSICS, 1990, 17 (05) : 763 - 772
  • [26] EFFECT OF FINITE PHOSPHOR THICKNESS ON DETECTIVE QUANTUM EFFICIENCY
    NISHIKAWA, RM
    YAFFE, MJ
    HOLMES, RB
    [J]. MEDICAL PHYSICS, 1989, 16 (05) : 773 - 780
  • [27] ANALYSIS OF SIGNAL AND NOISE-PROPAGATION FOR SEVERAL IMAGING MECHANISMS
    RABBANI, M
    VANMETTER, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1989, 6 (08): : 1156 - 1164
  • [28] DETECTIVE QUANTUM EFFICIENCY OF IMAGING-SYSTEMS WITH AMPLIFYING AND SCATTERING MECHANISMS
    RABBANI, M
    SHAW, R
    VANMETTER, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (05): : 895 - 901
  • [29] MONTE-CARLO OPTIMIZATION OF METAL PHOSPHOR SCREENS AT MEGAVOLTAGE ENERGIES
    RADCLIFFE, T
    BARNEA, G
    WOWK, B
    RAJAPAKSHE, R
    SHALEV, S
    [J]. MEDICAL PHYSICS, 1993, 20 (04) : 1161 - 1169
  • [30] ROEHRIG H, 1984, AAPM, V11, P82