Precontoured fixed-angle volar distal radius plates: A comparison of anatomic fit

被引:57
作者
Buzzell, Jonathan E. [1 ]
Weikert, Douglas R. [1 ]
Watson, Jeffry T. [1 ]
Lee, Donald H. [1 ]
机构
[1] Hand & Upper Extrem Ctr, Vanderbilt Orthopaed Inst, Nashville, TN 37232 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2008年 / 33A卷 / 07期
关键词
anatomy; distal radius; fixation; fracture;
D O I
10.1016/j.jhsa.2008.02.029
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare distal radius volar fixed-angle plates for anatomic fit. Methods Twenty embalmed radii were stripped of soft tissues. The volar lip (watershed line) on the volar distal radius served as a reference line. Seven volar fixed-angle plates were tested (Acumed Acu-Ioc Standard, Hand Innovations DVRAW and DVRAN, Synthes Juxta-articular [JA], Synthes Extra-articular [EA], Trimed Volar Bearing, Zimmer Volar Lateral Column). Four parameters of anatomic fit were studied: (1) site of best fit; (2) percent plate contact; (3) pin-subchondral bone distance; and (4) extraosseous penetrations. The Wilcoxon signed rank test and Pearson's correlation coefficient were used to compare interobserver plate placement. A Kruskal-Wallis analysis of variance was used to compare percent plate contact and pin-subchondral bone distance across all plates. The Bonferroni correction for multiple comparisons was used to compare pin-subchondral bone distances for all possible plate combinations. Results There was no difference between observers for plate placement. Each plate had a specific site of best fit, and the 7 plates varied widely in best fit location. Percent contact (range, 3% to 6%) between plates was significantly different. Pin-subchondral bone distance across all plates was significantly different. Analysis of all possible plate combinations showed that the Synthes EA pin-subchondral bone distances were significantly different than those of all plates except Zimmer. Amongst the 140 plate insertions, the radiocarpal joint was penetrated in 17, the styloid in 7, (with 6 associated with the DVRAW plate), and the distal radioulnar joint in 9 (all associated with the DVRAW plate). Conclusions There was considerable variation in ideal plate location among the 7 plates tested. Total contact was minimal for all plates tested. The Synthes EA pin-subchondral bone distance was significantly greater than those of other plates tested. Joint penetration was relatively common, necessitating use of fluoroscopy and proper plate width.
引用
收藏
页码:1144 / 1152
页数:9
相关论文
共 20 条
[1]
OPEN REDUCTION AND INTERNAL-FIXATION OF COMMINUTED, INTRAARTICULAR FRACTURES OF THE DISTAL RADIUS [J].
AXELROD, TS ;
MCMURTRY, RY .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1990, 15A (01) :1-11
[2]
Barrie Kimberly A, 2002, Tech Hand Up Extrem Surg, V6, P10, DOI 10.1097/00130911-200203000-00004
[3]
Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[4]
Treatment of displaced intra-articular fractures of the distal end of the radius with plates [J].
Fitoussi, F ;
Ip, WY ;
Chow, SP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (09) :1303-1312
[5]
Loss of fixation of the volar lunate facet fragment infractures of the distal part of the radius [J].
Harness, NG ;
Jupiter, JB ;
Orbay, JL ;
Raskin, KB ;
Fernandez, DL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (09) :1900-1908
[6]
Complications of the AO/ASIF titanium distal radius plate system (π plate) in internal fixation of the distal radius:: A brief report [J].
Kambouroglou, GK ;
Axelrod, TS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (04) :737-741
[7]
Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model [J].
Leung, F ;
Zhu, L ;
Ho, H ;
Lu, WW ;
Chow, SP .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2003, 28B (03) :263-266
[8]
A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures [J].
Liporace, FA ;
Gupta, S ;
Jeong, GK ;
Stracher, M ;
Kummer, F ;
Egol, KA ;
Koval, KJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) :187-191
[9]
Volar fixation of dorsally displaced distal radius fractures using the 2.4-mm locking compression plates [J].
Musgrave, DS ;
Idler, RS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (04) :743-749
[10]
Plating of the distal radius [J].
Nana, AD ;
Joshi, A ;
Lichtman, DM .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2005, 13 (03) :159-171