Electrospray ionization source geometry for mass spectrometry: past, present, and future

被引:101
作者
Manisali, I
Chen, DDY
Schneider, BB
机构
[1] Univ British Columbia, Dept Chem, Vancouver, BC V6T 1Z1, Canada
[2] MDS SCIEX, Concord, ON L4K 4V8, Canada
关键词
atmospheric pressure ionization; commercial ion source design; electrospray ionization; ion source; ion source geometry; mass spectrometry;
D O I
10.1016/j.trac.2005.07.007
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The geometry of an electrospray ion source plays important roles in the processes of analyte desolvation, ionization, transportation, and detection in a mass spectrometer. We provide a brief account of the scientific principles involved in developing an electrospray ion source, and in the various geometries used to improve the sensitivity of mass spectrometry. We also present some popular configurations currently available and outline future trends in this research area. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:243 / 256
页数:14
相关论文
共 139 条
[31]   A MICROSCALE ELECTROSPRAY INTERFACE FOR ONLINE, CAPILLARY LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY OF COMPLEX PEPTIDE MIXTURES [J].
DAVIS, MT ;
STAHL, DC ;
HEFTA, SA ;
LEE, TD .
ANALYTICAL CHEMISTRY, 1995, 67 (24) :4549-4556
[32]  
de Biasi V, 1999, RAPID COMMUN MASS SP, V13, P1165, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1165::AID-RCM638>3.0.CO
[33]  
2-4
[34]   MOLECULAR BEAMS OF MACROIONS [J].
DOLE, M ;
MACK, LL ;
HINES, RL .
JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (05) :2240-&
[35]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[36]   Origin and number of charges observed on multiply-protonated native proteins produced by ESI [J].
Felitsyn, N ;
Peschke, M ;
Kebarle, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 219 (01) :39-62
[37]   Fast characterization of intact proteins using a high-throughput eight-channel parallel liquid chromatography mass spectrometry system [J].
Feng, BB ;
Patel, AH ;
Keller, PM ;
Slemmon, JR .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (10) :821-826
[38]   An integrated ten-pump, eight-channel parallel LC/MS system for automated high-throughput analysis of proteins [J].
Feng, BB ;
McQueney, MS ;
Mezzasaima, TM ;
Slemmon, JR .
ANALYTICAL CHEMISTRY, 2001, 73 (23) :5691-5697
[39]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[40]  
Figeys D, 2001, ELECTROPHORESIS, V22, P208, DOI 10.1002/1522-2683(200101)22:2<208::AID-ELPS208>3.0.CO