High resolution computed tomography of the vertebrae yields accurate information on trabecular distances if processed by 3D fuzzy segmentation approaches

被引:31
作者
Krebs, Andreas [1 ]
Graeff, Christian [1 ]
Frieling, Isolde [3 ]
Kurz, Bodo [4 ]
Timm, Wolfram [2 ]
Engelke, Klaus [2 ]
Glueer, Claus-C. [1 ]
机构
[1] Univ Klinikum Schleswig Holstein, Radiol Diagnost Klin, Lubeck, Germany
[2] Synarc Inc, Hamburg, Germany
[3] Osteoporoszentrum Hamburg Neuer Wall, Hamburg, Germany
[4] Univ Kiel, Inst Anat, D-24098 Kiel, Germany
关键词
Osteoporosis; Trabecular bone; High resolution computed tomography; 3D architecture; Fuzzy distance transformation; IN-VIVO; CANCELLOUS BONE; IMAGE SEGMENTATION; FRACTURE RISK; LUMBAR SPINE; MICROSTRUCTURE; ARCHITECTURE; THICKNESS; STRENGTH; DENSITY;
D O I
10.1016/j.bone.2008.08.131
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The structure of trabecular bone represents all aspect of bone properties that affects vertebral bone strength independently of bone mineral density [M. Kleerekoper, A. Villanueva. J. Stanciu, D. Rao, and A. Parfitt. The role of three-dimensional trabecular microstructure in the pathogenesis of vertebral compression fractures. Calcif. Tissue hit., 37:594-597, Dec 1985; E. Seeman and P. Delmas. Bone quality-the material and structural basis of bone strength and fragility, N. Engl. J. Med., 354:2250-2261, May 2006.]. Using the mathematical concept of fuzzy distance transformation (FDT), we evaluated the accuracy of measurements of trabecular distance (Tb.Di(f)) which can be determined for vertebrae in Vivo using high resolution computed tomography (HRCT). Methods: In a first step extrema voxels with a very high likelihood of representing bone or marrow are identified. A probability level of being a bone voxel is assigned to all other voxel. This probability is based on the FDT of the voxel's gray-level, preprint submitted to Elsevier June 10, 2008; revised July 15, 2008 i.e. the shortest gray-value weighted distance to the marrow background. Next the resulting bone Structure is skeletonized. The space between the ridges of the skeleton is filled with the largest possible spheres. The average over the radii of the spheres defines Tb.Di(f), a measure of trabecular distance. 14 whole vertebrae embedded in polymethyl methylacrylate were scanned by HRCT (voxel size 156 x 156 x 400 mu m(3)) inside an anthropomorphic abdomen phantom. Scans obtained oil Scanco Xtreme CT (XCT, voxel size 82(3) mu m(3)) without the phantom were used as reference. Results: Tb.Di(f) calculated on XCT data were almost identical to trabecular distance values (1/Tb.N*) determined with the manufacturer's standard software (r(2)=0.98). Tb.Di(f) Values obtained with HRCT correlated strongly with Tb.Di(f) values obtained by XCT (r(2)=0.89). Over the range from 400 to 1400 mu m trabecular distance could be estimated with a residual error of 78 mu m. Conclusions: The FDT based variable Tb.Di(f) provides 3D estimates of trabecular distances with residual errors of less than 100 mu m using a HRCT protocol which also can be employed in vivo for assessing vertebral microarchitecture. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 33 条
[1]  
[Anonymous], 2005, The ITK Software Guide
[2]   A MULTISCALE RANDOM-FIELD MODEL FOR BAYESIAN IMAGE SEGMENTATION [J].
BOUMAN, CA ;
SHAPIRO, M .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1994, 3 (02) :162-177
[3]   In vivo assessment of trabecular bone microarchitecture by high-resolution peripheral quantitative computed tomography [J].
Boutroy, S ;
Bouxsein, ML ;
Munoz, F ;
Delmas, PD .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2005, 90 (12) :6508-6515
[4]  
CIESIELSKI KC, 2005, MIPG327 U PENNS DEP, P1
[5]   Relationship between compressive properties of human os calcis cancellous bone and microarchitecture assessed from 2D and 3D synchrotron microtomography [J].
Follet, H ;
Bruyère-Garnier, K ;
Peyrin, F ;
Roux, JP ;
Arlot, ME ;
Burt-Pichat, B ;
Rumelhart, C ;
Meunier, PJ .
BONE, 2005, 36 (02) :340-351
[6]   Monitoring teriparatide-associated changes in vertebral microstructure by high-resolution CT in vivo:: Results from the EUROFORS study [J].
Graeff, Christian ;
Timm, Wolfram ;
Nickelsen, Thomas N. ;
Farrerons, Jordi ;
Marin, Fernando ;
Barker, Clare ;
Glueer, Claus C. .
JOURNAL OF BONE AND MINERAL RESEARCH, 2007, 22 (09) :1426-1433
[7]  
Henschel M G, 1995, Rofo, V162, P269, DOI 10.1055/s-2007-1015882
[8]   A new method for the model-independent assessment of thickness in three-dimensional images [J].
Hildebrand, T ;
Ruegsegger, P .
JOURNAL OF MICROSCOPY-OXFORD, 1997, 185 :67-75
[9]   Direct three-dimensional morphometric analysis of human cancellous bone:: Microstructural data from spine, femur, iliac crest, and calcaneus [J].
Hildebrand, T ;
Laib, A ;
Müller, R ;
Dequeker, J ;
Rüegsegger, P .
JOURNAL OF BONE AND MINERAL RESEARCH, 1999, 14 (07) :1167-1174
[10]   Multi-detector row CT imaging of vertebral microstructure for evaluation of fracture risk [J].
Ito, M ;
Ikeda, K ;
Nishiguchi, M ;
Shindo, H ;
Uetani, M ;
Hosoi, T ;
Orimo, H .
JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (10) :1828-1836