Rapid metabolite identification with sub parts-per-million mass accuracy from biological matrices by direct infusion nanoelectrospray ionization after clean-up on a ZipTip and LTQ/Orbitrap mass spectrometry

被引:52
作者
Erve, John C. L. [1 ]
DeMaio, William [1 ]
Talaat, Rasmy E. [1 ]
机构
[1] Wyeth Res, Drug Safety & Metab, Collegeville, PA 19426 USA
关键词
D O I
10.1002/rcm.3702
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Metabolite identification studies remain an integral part of pre-clinical and clinical drug development programs. Analysis of biological matrices, such as plasma, urine, feces and bile, pose challenges due to the large amounts of endogenous components that can mask a drug and its metabolites. Although direct infusion nanoelectrospray using capillaries has been used routinely for proteomic studies, metabolite identification has traditionally employed liquid chromatographic (LC) separation prior to analysis. A method is described here for rapid metabolite profiling in biological fluids that involves initial sample clean-up using pipette tips packed with reversed-phase material (i.e. ZipTips) to remove matrix components followed by direct infusion nanoelectrospray on an LTQ/Orbitrap mass spectrometer using a protonated polydimethylcyclosiloxane cluster ion for internal calibration. Were-examined samples collected from a prazosin metabolism study in the rat. Results are presented that demonstrate that sub parts-per-million accuracies can be achieved on molecular ions, facilitating identification of metabolites, and on product ions, facilitating structural assignments. The data also show that the high-resolution measurements (R =100 000 at m/z 400) enable metabolites of interest to be resolved from endogenous components. The extended analysis times available with nanospray enables signal averaging for 1 min or more that is valuable when metabolites are present in low concentrations as encountered here in plasma and brain. Using this approach, the metabolic fate of a drug can be quickly obtained. A limitation of this approach is that metabolites that are structural isomers cannot be distinguished, although such information can be collected by LC/MS during follow-on experiments. Copyright (c) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:3015 / 3026
页数:12
相关论文
共 19 条
[1]   Clinical case series: The use of prazosin for combat-related recurrent nightmares among Operation Iraqi Freedom combat veterans [J].
Daly, CM ;
Doyle, ME ;
Radkind, M ;
Raskind, E ;
Daniels, C .
MILITARY MEDICINE, 2005, 170 (06) :513-515
[2]   Demonstration of direct bioanalysis of drugs in plasma using nanoelectrospray infusion from a silicon chip coupled with tandem mass spectrometry [J].
Dethy, JM ;
Ackermann, BL ;
Delatour, C ;
Henion, JD ;
Schultz, GA .
ANALYTICAL CHEMISTRY, 2003, 75 (04) :805-811
[3]   Metabolism of prazosin in rat and characterization of metabolites in plasma, urine, faeces, brain and bile using liquid chromatography/mass spectrometry (LC/MS) [J].
Erve, J. C. L. ;
Vashishtha, S. C. ;
Ojewoye, O. ;
Adedoyin, A. ;
Espina, R. ;
Demaio, W. ;
Talaat, R. E. .
XENOBIOTICA, 2008, 38 (05) :540-558
[4]  
Gobom J, 1999, J MASS SPECTROM, V34, P105, DOI 10.1002/(SICI)1096-9888(199902)34:2<105::AID-JMS768>3.0.CO
[5]  
2-4
[6]   Uniformity of ionization response of structurally diverse analytes using a chip-based nanoelectrospray ionization source [J].
Hop, CECA ;
Chen, Y ;
Yu, LJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) :3139-3142
[7]   The Orbitrap: a new mass spectrometer [J].
Hu, QZ ;
Noll, RJ ;
Li, HY ;
Makarov, A ;
Hardman, M ;
Cooks, RG .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (04) :430-443
[8]   Metabolite identification by data-dependent accurate mass spectrometric analysis at resolving power of 60,000 in external calibration mode using an LTQ/Orbitrap [J].
Lim, Heng-Keang ;
Chen, Jie ;
Sensenhauser, Carlo ;
Cook, Kevin ;
Subrahmanyam, Vangala .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (12) :1821-1832
[9]   Performance evaluation of a hybrid linear ion trap/orbitrap mass spectrometer [J].
Makarov, A ;
Denisov, E ;
Kholomeev, A ;
Baischun, W ;
Lange, O ;
Strupat, K ;
Horning, S .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2113-2120
[10]   Parts per million mass accuracy on an orbitrap mass spectrometer via lock mass injection into a C-trap [J].
Olsen, JV ;
de Godoy, LMF ;
Li, GQ ;
Macek, B ;
Mortensen, P ;
Pesch, R ;
Makarov, A ;
Lange, O ;
Horning, S ;
Mann, M .
MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (12) :2010-2021