Integrated microanalytical system based on electrochemical detection and cell positioning

被引:13
作者
Castellarnau, M
Zine, N
Bausells, J
Madrid, C
Juárez, A
Samitier, J
Errachid, A
机构
[1] CREBEC, Nanobioengn Res Lab, Barcelona 08028, Spain
[2] Univ Autonoma Barcelona, Ctr Nacl Microelect, IMB, E-08193 Barcelona, Spain
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2006年 / 26卷 / 2-3期
关键词
dielectrophoresis; bioelectronics; pH detection; ISFET;
D O I
10.1016/j.msec.2005.10.072
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The development and preliminary evaluation of an integrated microanalytical system based on electrochemical detection and cell positioning is reported here. The chip includes ion-sensitive field effect transistors (ISFET), a single pair of castellated microelectrodes and a reference Ag/AgCl microelectrode. The ISFETs have shown good operating characteristics, with a 52 mV/pH response. Yeast cells and bacteria have been positioned on the gate region of the ISFET sensor using single pair of castellated microelectrodes. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:405 / 410
页数:6
相关论文
共 18 条
[1]   Microfluidic devices for cellomics: a review [J].
Andersson, H ;
van den Berg, A .
SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (03) :315-325
[2]   Whole cell biosensors [J].
Bousse, L .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) :270-275
[3]   DIELECTROPHORETIC CHARACTERIZATION OF FRIEND MURINE ERYTHROLEUKAEMIC CELLS AS A MEASURE OF INDUCED-DIFFERENTIATION [J].
BURT, JPH ;
PETHIG, R ;
GASCOYNE, PRC ;
BECKER, FF .
BIOCHIMICA ET BIOPHYSICA ACTA, 1990, 1034 (01) :93-101
[4]   Multilayer ISFET membranes for microsystems applications [J].
Cane, C ;
Gotz, A ;
Merlos, A ;
Gracia, I ;
Errachid, A ;
Losantos, P ;
LoraTamayo, E .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 35 (1-3) :136-140
[5]  
Casanella R, 2003, IEE Proc Nanobiotechnol, V150, P70, DOI 10.1049/ip-nbt:20031100
[6]   New technology for multi-sensor silicon needles for biomedical applications [J].
Errachid, A ;
Ivorra, A ;
Aguiló, J ;
Villa, R ;
Zine, N ;
Bausells, J .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 78 (1-3) :279-284
[7]   Positioning living cells on a high-density electrode array by negative dielectrophoresis [J].
Frénéa, M ;
Faure, SP ;
Le Pioufle, B ;
Coquet, P ;
Fujita, H .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2003, 23 (05) :597-603
[8]   DIELECTROPHORETIC SEPARATION OF MAMMALIAN-CELLS STUDIED BY COMPUTERIZED IMAGE-ANALYSIS [J].
GASCOYNE, PRC ;
HUANG, Y ;
PETHIG, R ;
VYKOUKAL, J ;
BECKER, FF .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1992, 3 (05) :439-445
[9]  
Jones T.B., 2005, Electromechanics of particles
[10]   CHROMOSOMAL MUTATION THAT AFFECTS EXCRETION OF HEMOLYSIN IN ESCHERICHIA-COLI [J].
JUAREZ, A ;
GOEBEL, W .
JOURNAL OF BACTERIOLOGY, 1984, 159 (03) :1083-1085