Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible

被引:105
作者
Wanschitz, F
Birkfellner, W
Watzinger, F
Schopper, C
Patruta, S
Kainberger, F
Figl, M
Kettenbach, J
Bergmann, H
Ewers, R
机构
[1] Univ Vienna, Gen Hosp, Dept Oral & Maxillofacial Surg, A-1090 Vienna, Austria
[2] Univ Vienna, Gen Hosp, Dept Biomed Engn & Phys, A-1090 Vienna, Austria
[3] Univ Vienna, Sch Dent, A-1010 Vienna, Austria
[4] Ludwig Boltzmann Inst Nucl Med & Endocrinol, Vienna, Austria
[5] Univ Vienna, Gen Hosp, Dept Radiol, Div Osteoradiol, A-1090 Vienna, Austria
[6] Univ Vienna, Gen Hosp, Dept Radiol, Div Angiog & Intervent Radiol, A-1090 Vienna, Austria
关键词
computer-aided surgery; implant dentistry; accuracy; mutual information matching;
D O I
10.1034/j.1600-0501.2002.130107.x
中图分类号
R78 [口腔科学];
学科分类号
1003 [口腔医学];
摘要
The overall accuracy of a novel surgical computer-aided navigation system for placement of endosseous implants was evaluated. Five dry cadaver mandibles were scanned using high resolution computed tomography (HRCT). The position of four interforaminal dental implants was planned on the computer screen and transferred to the cadaver mandibles using VISIT, a surgical navigation software developed at the Vienna General Hospital. The specimens were HRCT-scanned again to compare the position of the implants with the preoperative plan on reformatted slices after matching of the pre- and postoperative data sets using the mutual information technique. The overall accuracy was 0.96+/-0.72 mm (range 0.0-3.5 mm). No perforation of the mandibular cortex or damage to the mandibular canal occurred. We conclude that computer-aided implant surgery can reach a level of accuracy where further clinical developments are feasible.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 25 条
[1]
[Anonymous], 3 DIMENSIONAL BIOMED
[2]
DENTAL IMPLANT TREATMENT PLANNING WITH REFORMATTED COMPUTED-TOMOGRAPHY [J].
BESIMO, C ;
LAMBRECHT, JT ;
NIDECKER, A .
DENTOMAXILLOFACIAL RADIOLOGY, 1995, 24 (04) :264-267
[3]
In-vitro assessment of a registration protocol for image guided implant dentistry [J].
Birkfellner, W ;
Solar, P ;
Gahleitner, A ;
Huber, K ;
Kainberger, F ;
Kettenbach, J ;
Homolka, P ;
Diemling, M ;
Watzek, G ;
Bergmann, H .
CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (01) :69-78
[4]
A modular software system for computer-aided surgery and its first application in oral implantology [J].
Birkfellner, W ;
Huber, K ;
Larson, A ;
Hanson, D ;
Diemling, M ;
Homolka, P ;
Bergmann, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (06) :616-620
[5]
Birkfellner W, 1999, INT CONGR SER, V1191, P878
[6]
Calibration of tracking systems in a surgical environment [J].
Birkfellner, W ;
Watzinger, F ;
Wanschitz, F ;
Ewers, R ;
Bergmann, H .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :737-742
[7]
BIRKFELLNER W, 2000, SPRINGER LECT NOTES, V1935, P867
[8]
A CLASSIFICATION OF THE EDENTULOUS JAWS [J].
CAWOOD, JI ;
HOWELL, RA .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1988, 17 (04) :232-236
[9]
Fortin T, 1995, J Image Guid Surg, V1, P53, DOI 10.1002/(SICI)1522-712X(1995)1:1<53::AID-IGS8>3.3.CO
[10]
2-B