Dependence of the response of an amperometric biosensor formed in a micro flow channel on structural and conditional parameters

被引:14
作者
Hashimoto, Masatoshi [1 ]
Upadhyay, Sanjay [1 ]
Suzuki, Hiroaki [1 ]
机构
[1] Univ Tsukuba, Grad Sch Pure & Appl Sci, Tsukuba, Ibaraki 3058573, Japan
基金
日本学术振兴会;
关键词
flow channel; glucose; conversion efficiency; L-ascorbic acid;
D O I
10.1016/j.bios.2005.11.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Comprehensive analysis of the behavior of an amperometric biosensor incorporated in a micro flow channel was conducted by changing the structural and conditional parameters. The device used in the characterization consisted of a thin-film three-electrode system and a silicone rubber flow channel. An enzyme, glucose oxidase, was immobilized either at the bottom of the silicone rubber flow channel or on the electrode substrate. The flow rate, concentration, position of the immobilized enzyme, and channel height were changed, and the changes in the output current and the conversion efficiency were examined. When the flow rate and/or the channel height decreased, the output current and the conversion efficiency significantly increased. The conversion efficiency also increased by decreasing the concentration. The tendency of the flow dependence was reversed when the position of the immobilized enzyme was changed from the silicone rubber side to the electrode substrate. In addition, the influence of L-ascorbic acid was reduced by placing additional working electrodes in the upper stream. L-Ascorbic acid was eliminated more effectively as the flow rate decreased and the area of the working electrode for elimination increased. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:2224 / 2231
页数:8
相关论文
共 28 条
[1]  
Dempsey E, 1997, ANAL CHIM ACTA, V346, P341
[2]   THE INFLUENCE OF FLOW-RATE ON BIOSENSORS BASED ON REDOX ENZYMES INCORPORATED IN A REDOX POLYMER MOUNTED IN A THIN-LAYER FLOW CELL [J].
ELMGREN, M ;
NORDLING, M ;
LINDQUIST, SE .
ANALYTICAL BIOCHEMISTRY, 1993, 215 (02) :261-265
[3]   Selective detection Of L-glutamate using a microfluldic device integrated with an enzyme-modified pre-reactor and an electrochemical detector [J].
Hayashi, K ;
Kurita, R ;
Horiuchi, T ;
Niwa, O .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (10) :1249-1255
[4]   ELIMINATION OF ELECTROCHEMICALLY-ACTIVE INTERFERENTS IN AMPEROMETRIC BIOSENSOR MEASUREMENTS - APPLICATION TO ONLINE MONITORING OF GLUCOSE AND GLUTAMATE [J].
KOSHY, A ;
ZILKHA, E ;
OBRENOVITCH, TP ;
BENNETTO, HP ;
RICHARDS, DA ;
SYMON, L .
ANALYTICAL LETTERS, 1993, 26 (05) :831-849
[5]   Microreactor and electrochemical detectors fabricated using Si and EPON SU-8 [J].
L'Hostis, E ;
Michel, PE ;
Fiaccabrino, GC ;
Strike, DJ ;
de Rooij, NF ;
Koudelka-Hep, M .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 64 (1-3) :156-162
[6]   DETERMINATION OF L-GLUTAMATE BY AMPEROMETRIC FLOW-INJECTION ANALYSIS USING IMMOBILIZED GLUTAMATE OXIDASE - MANIFOLD FOR SIMULTANEOUS DETECTION OF COMPONENT SIGNAL AND BLANK SIGNAL [J].
MATSUMOTO, K ;
SAKODA, K ;
OSAJIMA, Y .
ANALYTICA CHIMICA ACTA, 1992, 261 (1-2) :155-159
[7]   A long-term lifetime amperometric glucose sensor with a perfluorocarbon polymer coating [J].
Matsumoto, T ;
Ohashi, A ;
Ito, N ;
Fujiwara, H ;
Matsumoto, T .
BIOSENSORS & BIOELECTRONICS, 2001, 16 (4-5) :271-276
[8]   Biosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine [J].
Moser, I ;
Jobst, G ;
Urban, GA .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (04) :297-302
[9]  
Niwa O, 1999, ELECTROANAL, V11, P356, DOI 10.1002/(SICI)1521-4109(199905)11:5<356::AID-ELAN356>3.3.CO
[10]  
2-#