Passive sampling techniques for monitoring pollutants in water

被引:648
作者
Vrana, B
Mills, GA
Allan, IJ
Dominiak, E
Svensson, K
Knutsson, J
Morrison, G
Greenwood, R
机构
[1] Univ Portsmouth, Sch Biol Sci, Portsmouth PO1 2DY, Hants, England
[2] Univ Portsmouth, Sch Pharm & Biomed Sci, Portsmouth PO1 2DY, Hants, England
[3] Gdansk Univ Technol, Fac Chem, Dept Analyt Chem, PL-80952 Gdansk, Poland
[4] Chalmers Univ Technol, SE-41296 Gothenburg, Sweden
关键词
environmental monitoring; environmental pollutants; passive sampling; sample preparation; water analysis;
D O I
10.1016/j.trac.2005.06.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We review the state of the art in using passive sampling technology for environmental monitoring of waterborne organic and inorganic pollutants. We discuss strategies for sampler design, calibration, in situ sampling and quality-control issues, and advantages and challenges associated with passive sampling in aqueous environments. We then review typical applications of passive samplers in assessing the aquatic environment. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:845 / 868
页数:24
相关论文
共 154 条
[91]   TRANSPORT MECHANISMS AND PROCESSES FOR METAL SPECIES IN A GULLYPOT SYSTEM [J].
MORRISON, GM ;
REVITT, DM ;
ELLIS, JB ;
SVENSSON, G ;
BALMER, P .
WATER RESEARCH, 1988, 22 (11) :1417-1427
[92]  
MORRISON GMP, 1989, CHEM BRIT, V25, P791
[93]   DGT as an in situ tool for measuring radiocesium in natural waters [J].
Murdock, C ;
Kelly, M ;
Chang, LY ;
Davison, W ;
Zhang, H .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (22) :4530-4535
[94]   Passive sampling and/or extraction techniques in environmental analysis: a review [J].
Namiesnik, J ;
Zabiegala, B ;
Kot-Wasik, A ;
Partyka, M ;
Wasik, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (02) :279-301
[95]   Permeation liquid membrane for trace metal speciation in natural waters - Transport of liposoluble Cu(II) complexes [J].
Parthasarathy, N ;
Pelletier, M ;
Buffle, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1025 (01) :33-40
[96]   SUPPORTED LIQUID MEMBRANE FOR ANALYTICAL SEPARATION OF TRANSITION-METAL IONS .1. COMPLEXATION PROPERTIES OF 1,10-DIDECYL-1,10-DIAZA-18-CROWN-6 [J].
PARTHASARATHY, N ;
BUFFLE, J .
ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) :1-7
[97]   Hollow fiber based supported liquid membrane: a novel analytical system for trace metal analysis [J].
Parthasarathy, N ;
Pelletier, M ;
Buffle, J .
ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) :183-195
[98]   CAPABILITIES OF SUPPORTED LIQUID MEMBRANES FOR METAL SPECIATION IN NATURAL-WATERS - APPLICATION TO COPPER SPECIATION [J].
PARTHASARATHY, N ;
BUFFLE, J .
ANALYTICA CHIMICA ACTA, 1994, 284 (03) :649-659
[99]   Sample preparation: Quo Vadis? [J].
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (11) :2543-2558
[100]  
Pawliszyn J., 1997, SOLID PHASE MICROEXT