Noninvasive pressure and temperature estimation in large-volume apparatus by equation-of-state cross-calibration

被引:48
作者
Crichton, WA [1 ]
Mezouar, M [1 ]
机构
[1] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
D O I
10.1068/htjr019
中图分类号
O414.1 [热力学];
学科分类号
摘要
The utility of internal calibration of large-volume cell high-pressure (p) and high-temperature (T) conditions by a noninvasive equation of state (EOS) cross-calibration method is assessed. This involved the introduction of simultaneously measured unit-cell volumes, measured by in-situ x-ray diffraction in Paris-Edinburgh large-volume apparatus, for gold and NaCl into their EOS to obtain a simplified solution set for p and T run conditions. These have been gauged from K-type thermocouple measurements and the EOS of hBN to establish an estimate of the combined errors involved in this method. It was found that the total error (in combined p, T and three EOS calculations) results in apparent p miscalculation of 0.2 GPa and with a mean error in T of 13%. This technique alone is valuable in high p and T experimentation above similar to 5 GPa where no reliable pressure correction exists for thermocouples and in situations where the use of a thermocouple is not advisable, for example, where thermocouple materials are sample-reactive. Combined with furnace power -p-T curves, this method offers a viable alternative to invasive measurement.
引用
收藏
页码:235 / 242
页数:8
相关论文
共 17 条
[11]   Two-dimensional detector software: From real detector to idealised image or two-theta scan [J].
Hammersley, AP ;
Svensson, SO ;
Hanfland, M ;
Fitch, AN ;
Hausermann, D .
HIGH PRESSURE RESEARCH, 1996, 14 (4-6) :235-248
[12]   COMBINED VERY HIGH PRESSURE/HIGH TEMPERATURE CALIBRATION OF TETRAHEDRAL ANVIL APPARATUS FUSION CURVES OF ZINC ALUMINIUM GERMANIUM AND SILICON TO 60 KILOBARS [J].
LEES, J ;
WILLIAMSON, BH .
NATURE, 1965, 208 (5007) :278-+
[13]  
LEGODEC Y, 2000, P AIRAPT 17 SCI TECH, P925
[14]   Paris-Edinburgh large-volume cell coupled with a fast imaging-plate system for structural investigation at high pressure and high temperature [J].
Mezouar, M ;
Le Bihan, T ;
Libotte, H ;
Le Godec, Y ;
Häusermann, D .
JOURNAL OF SYNCHROTRON RADIATION, 1999, 6 :1115-1119
[15]   An improved X-ray detector for use at synchrotrons [J].
Thoms, M ;
Bauchau, S ;
Hausermann, D ;
Kunz, M ;
Le Bihan, T ;
Mezouar, M ;
Strawbridge, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 413 (01) :175-184
[16]  
VONDREELE RB, 1998, 86748 LAUR LOS AL NA
[17]   HIGH-TEMPERATURE ELASTICITY OF SODIUM-CHLORIDE [J].
YAMAMOTO, S ;
OHNO, I ;
ANDERSON, OL .
JOURNAL OF PHYSICS AND CHEMISTRY OF SOLIDS, 1987, 48 (02) :143-151