Clinical evaluation of the GlucoWatch® biographer:: a continual, non-invasive glucose monitor for patients with diabetes

被引:254
作者
Tierney, MJ
Tamada, JA
Potts, RO
Jovanovic, L
Garg, S
机构
[1] Cygnus Inc, Redwood City, CA 94063 USA
[2] Sansum Med Res Inst, Santa Barbara, CA 93105 USA
[3] Univ Colorado, Hlth Sci Ctr, Barbara Davis Ctr Childhood Dis, Denver, CO 80262 USA
关键词
glucose monitor; diabetes; GlucoWatch((R)) biographer;
D O I
10.1016/S0956-5663(01)00189-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A device providing frequent, automatic, and non-invasive glucose measurements for persons with diabetes has been developed: the GlucoWatch (R) biographer. This device extracts glucose through intact skin via reverse iontophoresis where it is detected by an amperometric biosensor. The biographer can provide glucose readings every 20 min for 12 h. The performance of this device was evaluated in two large clinical studies in a controlled clinical environment (n = 231), and the home environment (n = 124). Accuracy of the biographer was evaluated by comparing the automatic biographer readings to serial finger-stick blood glucose (BG) measurements. Biographer performance was comparable in both environments. Mean difference between biographer and finger-stick measurements was -0.01 and 0.26 mmol l(-1) for the clinical and home environments, respectively. The mean absolute value of the relative difference was 1.06 and 1.18 mmol l(-1) for the same studies. Correlation coefficient (r) between biographer and finger-stick measurements was 0.85 and 0.80 for the two studies. In both studies, over 94% of the biographer readings were in the clinically acceptable A + B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low BG levels. Biographer accuracy is relatively constant over all rates of BG changes, except when BG decreases more than 10 mmol l(-1) h(-1), which occurred for only 0.2% of points in the home environment study. Biographer precision, as measured by CV%, is approx. 10%. Skin irritation, characterized by erythema and edema, was either non-existent or mild in > 90% of subjects and resolved in virtually all subjects without treatment in several days. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:621 / 629
页数:9
相关论文
共 18 条
[1]   Validation of home blood glucose meters with respect to clinical and analytical approaches [J].
Brunner, GA ;
Ellmerer, M ;
Sendlhofer, G ;
Wutte, A ;
Trajanoski, Z ;
Schaupp, L ;
Quehenberger, F ;
Wach, P ;
Krejs, GJ ;
Pieber, TR .
DIABETES CARE, 1998, 21 (04) :585-590
[2]   Modelling and simulation of a diffusion limited glucose biosensor [J].
Cambiaso, A ;
Delfino, L ;
Grattarola, M ;
Verreschi, G ;
Ashworth, D ;
Maines, A ;
Vadgama, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1996, 33 (1-3) :203-207
[3]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[4]  
Deming W. E., 1943, STAT ADJUSTMENT DATA
[5]  
Draize JH, 1944, J PHARMACOL EXP THER, V82, P377
[6]   Correlation at fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes [J].
Garg, SK ;
Potts, RO ;
Ackerman, NR ;
Fermi, SJ ;
Tamada, JA ;
Chase, HP .
DIABETES CARE, 1999, 22 (10) :1708-1714
[7]  
GINSBERG BH, 1992, CLIN CHEM, V38, P1596
[8]   A WARD COMPARISON BETWEEN THE ONE TOUCH-II AND GLUCOMETER-II BLOOD-GLUCOSE METERS [J].
KILPATRICK, ES ;
MCLEOD, MJ ;
RUMLEY, AG ;
SMALL, M .
DIABETIC MEDICINE, 1994, 11 (02) :214-217
[9]  
KURNIK R, 1999, SENSOR ACTUAT B-CHEM, V60, P1
[10]  
Louie RF, 2000, ARCH PATHOL LAB MED, V124, P257