The low contact stress mobile-bearing total knee replacement A PROSPECTIVE STUDY WITH A MINIMUM FOLLOW-UP OF TEN YEARS

被引:42
作者
Hooper, G. [1 ]
Rothwell, A. [1 ]
Frampton, C. [1 ]
机构
[1] Christchurch Publ Hosp, Dept Orthopaed Surg, Christchurch, New Zealand
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2009年 / 91B卷 / 01期
关键词
D O I
10.1302/0301-620X.91B1.20484
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
We have examined the outcome of 400 consecutive patients who underwent total knee replacement with the Low Contact Stress mobile-bearing system between 1993 and 1994 and were followed up for a minimum of ten years. All operations were performed by surgeons in Christchurch, New Zealand, who used no other knee prosthesis during the study time. At ten years after operation 238 patients ( 244 knees) remained for independent clinical and radiological assessment. There was a significant improvement ( p < 0.001) in the postoperative knee scores at one, three, seven and ten years, although a slight deterioration in the score occurred between seven and ten years which did not reach statistical significance. The survival for polyethylene wear or loosening was 97% ( 95% CI 96 to 98) and survival using reoperation for any cause was 92% ( 95% CI 90 to 94) at 12 years. Polyethylene wear was more common in the meniscal-bearing component, with five knees requiring revision and a further eight demonstrating early wear. Osteolysis was not seen in the rotating platform component, but was present in three of the meniscal-bearing knees. There was no association between the radiological alignment at one year and those knees that subsequently required revision. However, there was an association between the overall limb alignment and the Western Ontario McMasters University score ( p < 0.001). The Low Contact Stress mobile-bearing total knee replacement has proved to be a reliable implant at ten years when used in primary knee replacement irrespective of the deformity and diagnosis.
引用
收藏
页码:58 / 63
页数:6
相关论文
共 31 条
[1]
Fracture of the metal tibial tray after kinematic total knee replacement - A common cause of early aseptic failure [J].
Abernethy, PJ ;
Robinson, CM ;
Fowler, RM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (02) :220-225
[2]
A randomised controlled trial of cemented versus cementless press-fit condylar total knee replacement [J].
Baker, P. N. ;
Khaw, F. M. ;
Kirk, L. M. G. ;
Esler, C. N. A. ;
Gregg, P. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (12) :1608-1614
[3]
BELLAMY N, 1988, J RHEUMATOL, V15, P1833
[4]
BUECHEL FF, 2001, CLIN ORTHOP RELAT R, V388, P41
[5]
BUECHEL FF, 1982, ORTHOP REV, V11, P97
[6]
Cemented rotating-platform total knee replacement - A nine to twelve-year follow-up study [J].
Callaghan, JJ ;
Squire, MW ;
Goetz, DD ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05) :705-711
[7]
Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report [J].
Callaghan, JJ ;
O'Rourke, MR ;
Iossi, MF ;
Liu, SS ;
Goetz, DD ;
Vittetoe, DA ;
Sullivan, PM ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :1995-1998
[8]
Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty [J].
Collier, Matthew B. ;
Engh, C. Anderson, Jr. ;
McAuley, James P. ;
Engh, Gerard A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (06) :1306-1314
[9]
Causes of failure of the Kinemax Plus total knee replacement in the first five years [J].
Davis, C. R. ;
Davies, A. P. ;
Newman, J. H. .
KNEE, 2007, 14 (02) :158-161
[10]
Hydroxyapatite-coated total knee replacement - Clinical experience at 10 to 15 years [J].
Epinette, J. -A. ;
Manley, M. T. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (01) :34-38