Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy

被引:125
作者
Beslic, Serif [1 ]
Zukic, Fuad [1 ]
Milisic, Selma [1 ]
机构
[1] Univ Sarajevo, Clin Radiol, Ctr Clin, Sarajevo 71000, Bosnia & Herceg
关键词
transthoracic biopsy; lung lesions; CT; FNAB; core biopsy; THORACIC LESIONS; ACCURACY;
D O I
10.2478/v10019-012-0004-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Background. The purpose of this retrospective study was to compare the results and complication rate in CT guided percutaneous trans-thoracic fine needle aspiration biopsies (FNAB) and core biopsies of lung lesions, and to determine the applicability of these needles. Patients and methods. In 242 patients (166 males; 76 females) with mean age of 58.9 years (13-84 years) CT guided biopsies of lung lesions were performed on dual slice CT equipment. The average diameter of lung lesion was 2.9 cm (1.2-6.3 cm). For FNAB's 20 - 22 G Chiba needles and for core biopsies 14 G biopsy needles were used. The samples were sent for the histological analysis. The cytological or histological results and the eventual complications were compared. Results. FNAB's cytological samples were adequate for definitive diagnosis in 117 patients (79.60 %) and inadequate in 30 patients (20.40 %). Core biopsies samples were adequate in 92 (96.85 %) patients and non-representative (necrotic tissue) in 3 (3.15 %). Pneumothorax as the most frequent complication was detected in 14 (9.7 %) of the patients in the group of FNAB's and in 30 (31.5 %) of the patients with the core biopsy group. Conclusions. The results showed that percutaneous transthoracic CT guided biopsies of lung lesions were an effective and safe procedure in the diagnosis of lung lesions. Core biopsy gives a higher percentage of representative samples than FNAB, and is a preferred method regardless of the higher rate of complications.
引用
收藏
页码:19 / 22
页数:4
相关论文
共 13 条
[1]
Percutaneous image-guided cutting-needle biopsy of the pleura in the presence of a suspected malignant effusion [J].
Adams, RF ;
Gleeson, FV .
RADIOLOGY, 2001, 219 (02) :510-514
[2]
Image-guided automated needle biopsy of 106 thoracic lesions: a retrospective review of diagnostic accuracy and complication rates [J].
Connor, S ;
Dyer, J ;
Guest, P .
EUROPEAN RADIOLOGY, 2000, 10 (03) :490-494
[3]
Percutaneous core-needle biopsy of enlarged lymph nodes in the diagnosis and subclassification of malignant lymphomas [J].
Demharter, J ;
Müller, P ;
Wagner, T ;
Schlimok, G ;
Haude, K ;
Bohndorf, K .
EUROPEAN RADIOLOGY, 2001, 11 (02) :276-283
[4]
Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses [J].
Heck, SL ;
Blom, P ;
Berstad, A .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1387-1392
[5]
Kocijani I., 2007, Radiol Oncol, V41, P99
[6]
US-guided transthoracic cutting biopsy for peripheral thoracic lesions less than 3 cm in diameter [J].
Liao, WY ;
Chen, MZ ;
Chang, YL ;
Wu, HD ;
Yu, CJ ;
Kuo, PH ;
Yang, PC .
RADIOLOGY, 2000, 217 (03) :685-691
[7]
Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions [J].
Montaudon, M ;
Latrabe, V ;
Pariente, A ;
Corneloup, O ;
Begueret, H ;
Laurent, F .
EUROPEAN RADIOLOGY, 2004, 14 (07) :1234-1240
[8]
New suction guide needle designed to reduce the incidence of biopsy-related pneumothorax: Experimental evaluation in canine model [J].
Morello, FA ;
Wright, KC ;
Lembo, TM .
RADIOLOGY, 2005, 235 (03) :1045-1049
[9]
Ultrathin needle (25 G) aspiration lung biopsy: Diagnostic accuracy and complication rates [J].
Oikonomou A. ;
Matzinger F.R. ;
Seely J.M. ;
Dennie C.J. ;
Macleod P.J. .
European Radiology, 2004, 14 (3) :375-382
[10]
CT-guided percutaneous transthoracic biopsy in the diagnosis of mediastinal masses: Evaluation of 73 procedures [J].
Priola A.M. ;
Priola S.M. ;
Cataldi A. ;
Ferrero B. ;
Garofalo G. ;
Errico L. ;
Marci V. ;
Fava C. .
La radiologia medica, 2008, 113 (1) :3-15