Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions

被引:153
作者
Montaudon, M
Latrabe, V
Pariente, A
Corneloup, O
Begueret, H
Laurent, F
机构
[1] CHU Bordeaux, Hop Haut Leveque, Unite Imagerie Thorac & Cardiovasc, F-33604 Pessac, France
[2] Univ Victor Segalen Bordeaux 2, INSERM E0356, Bordeaux, France
[3] Univ Bordeaux 2, INSERM, Unite 593, ISPED, Bordeaux, France
[4] Hop Haut Leveque, Dept Pathol, F-33604 Pessac, France
关键词
lung neoplasms; diagnosis; computed tomography; guidance; lung; biopsy;
D O I
10.1007/s00330-004-2250-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose of this study was to evaluate the performance and complication rate of CT-guided percutaneous lung biopsy of pulmonary lesions using a coaxial automated biopsy device and to determine factors influencing the false negative rate for the diagnosis of malignancy. A prospective study of 605 consecutive biopsies performed in 595 patients was undertaken. The performances for the diagnosis of malignancy, for the specific diagnosis of benignity and the complication rate were calculated. Patients' characteristics and lesion and procedure variables were included in a logistic regression model and analyzed as potential predictive variables for occurrence of a false-negative diagnosis of malignancy. The sensitivity, specificity, positive predictive value and negative predictive value for a diagnosis of malignancy were 92.2, 99.1, 99.8 and 73.3%, respectively. A specific diagnosis of benignity was obtained in 43 cases (40%) biopsies. The pneumothorax rate was 17.4% (n=105) with 3 (0.5%) requiring drainage. At multivariate analysis, the sole variable significantly associated with a higher rate of false negative diagnosis of malignancy was lesion size equal to or smaller than 10 mm in diameter. Using a coaxial automated device, CT-guided percutaneous biopsy of pulmonary lesions of size equal to or less than 10 mm in diameter provides a high diagnostic yield with an acceptable complication rate.
引用
收藏
页码:1234 / 1240
页数:7
相关论文
共 20 条
[1]
CT-guided transthoracic needle biopsy: A comparison between automated biopsy gun and fine needle aspiration [J].
Arakawa, H ;
Nakajima, Y ;
Kurihara, Y ;
Niimi, H ;
Ishikawa, T .
CLINICAL RADIOLOGY, 1996, 51 (07) :503-506
[2]
VALUE OF HAVING A CYTOPATHOLOGIST PRESENT DURING PERCUTANEOUS FINE-NEEDLE ASPIRATION BIOPSY OF LUNG - REPORT OF 55 CANCER-PATIENTS AND METAANALYSIS OF THE LITERATURE [J].
AUSTIN, JHM ;
COHEN, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (01) :175-177
[3]
BERQUIST TH, 1980, MAYO CLIN PROC, V55, P475
[4]
BOCKING A, 1995, ACTA CYTOL, V39, P463
[5]
Routine addition of an automated biopsy device to fine-needle aspiration of the lung: A prospective assessment [J].
Boiselle, PM ;
Shepard, JAO ;
Mark, EJ ;
Szyfelbein, WM ;
Fan, CM ;
Slanetz, PJ ;
TrotmanDickenson, B ;
Halpern, EF ;
McLoud, TC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) :661-666
[6]
CYTOPATHOLOGIC TOUCH PREPARATIONS (IMPRINTS) FROM CORE NEEDLE BIOPSIES - ACCURACY COMPARED WITH THAT OF FINE-NEEDLE ASPIRATES [J].
HAHN, PF ;
EISENBERG, PJ ;
PITMAN, MB ;
GAZELLE, GS ;
MUELLER, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (05) :1277-1279
[7]
Hosmer D. W., 1989, APPL LOGISTIC REGRES, DOI DOI 10.1097/00019514-200604000-00003
[8]
Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720
[9]
CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: Results with an automated 20-gauge coaxial cutting needle [J].
Laurent, F ;
Latrabe, V ;
Vergier, B ;
Montaudon, M ;
Vernejoux, JM ;
Dubrez, J .
CLINICAL RADIOLOGY, 2000, 55 (04) :281-287
[10]
Intrapulmonary lesions: Percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle [J].
Lucidarme, O ;
Howarth, N ;
Finet, JF ;
Grenier, PA .
RADIOLOGY, 1998, 207 (03) :759-765