Sagittal geometry of the middle and lower cervical endplates

被引:45
作者
Chen, Hong [1 ]
Zhong, Jian [1 ]
Tan, Jixiang [2 ]
Wu, Dandong [3 ]
Jiang, Dianming [1 ]
机构
[1] Chongqing Med Univ, Affiliated Hosp 1, Dept Orthoped, Chongqing 400016, Yuzhong Distric, Peoples R China
[2] Chongqing Med Univ, Affiliated Hosp 1, Dept Emergency & Crit Care Med, Chongqing 400016, Yuzhong Distric, Peoples R China
[3] Chongqing Med Univ, Affiliated Hosp 2, Dept Endocrinol, Chongqing 400016, Yuzhong Distric, Peoples R China
关键词
Sagittal geometry; Cervical spine; Endplate; Cervical spine anterior cervical fusion; VERTEBRAL BODY REPLACEMENT; LUMBAR VERTEBRAE; THORACOLUMBAR SPINE; FUSION; CAGES; BIOMECHANICS; TITANIUM; DISKECTOMY; STRENGTH; ANATOMY;
D O I
10.1007/s00586-013-2791-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
100204 [神经病学];
摘要
Construct subsidence is a relatively common complication following anterior cervical fusion. Its occurrence has been revealed to be closely related to endplate-implant contact interface. But current literature focusing on the anatomy of cervical endplate is very scarce. The purpose of this morphometric study was to analyse the sagittal geometry, especially the concavity and slope, of vertebral endplates from C3 to C7 by employing data from CT scans. Reformatted CT scans of 97 individuals were analyzed and endplate concavity depth, endplate concavity apex location, as well as endplate slope were measured in midsagittal plane. Those specific parameters were compared among different age and gender groups. Meanwhile, comparison between superior and inferior endplate of each vertebra was also performed. Age and gender did not influence endplate concavity depth, endplate concavity apex location, or endplate slope significantly (P > 0.05). Endplate concavity depths of superior endplates (range 0.9-1.2 mm) were significantly smaller than those of inferior endplates (range 2.1-2.7 mm). Endplate concavity apex was always located in the posterior half of the endplate, with the superior one ranged from 56 to 67 % and the inferior one 52 to 57 %. Average endplate slopes of superior endplates were between 4.5A degrees and 9.0A degrees, and average inferior endplate slopes ranged from 4.5A degrees to 7.5A degrees. Among all measured segments, C5 had the largest endplate slope values, while C7 the least. Superior endplate is more flat than its inferior counterpart in middle and lower cervical spine, and the concavity apex is always located in the posterior half of the endplate. Endplate slope is correlated with cervical curvature, greater slope implying more significant lordosis. These sagittal endplate geometrical parameters should be taken into consideration when investigating implant subsidence following anterior cervical fusion.
引用
收藏
页码:1570 / 1575
页数:6
相关论文
共 26 条
[1]
Factors affecting sagittal malalignment due to cage subsidence in standalone cage assisted anterior cervical fusion [J].
Barsa, Pavel ;
Suchomel, Petr .
EUROPEAN SPINE JOURNAL, 2007, 16 (09) :1395-1400
[2]
ROBINSON ANTERIOR CERVICAL DISKECTOMY AND ARTHRODESIS FOR CERVICAL RADICULOPATHY - LONG-TERM FOLLOW-UP OF 100 AND 22 PATIENTS [J].
BOHLMAN, HH ;
EMERY, SE ;
GOODFELLOW, DB ;
JONES, PK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (09) :1298-1307
[3]
In vitro biomechanics of an expandable vertebral body replacement with self-adjusting end plates [J].
Buttermann, Glenn R. ;
Freeman, Andrew L. ;
Beaubien, Brian P. .
SPINE JOURNAL, 2010, 10 (11) :1024-1031
[4]
Interbody device endplate engagement effects on motion segment biomechanics [J].
Buttermann, Glenn R. ;
Beaubien, Brian P. ;
Freeman, Andrew L. ;
Stoll, James E. ;
Chappuis, James L. .
SPINE JOURNAL, 2009, 9 (07) :564-573
[5]
Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages [J].
Cabraja, Mario ;
Oezdemir, Soner ;
Koeppen, Daniel ;
Kroppenstedt, Stefan .
BMC MUSCULOSKELETAL DISORDERS, 2012, 13
[6]
Geometry of thoracolumbar vertebral endplates of the human spine [J].
Chen, Hong ;
Jiang, Dianming ;
Ou, Yunsheng ;
Zhong, Jian ;
Lv, Fajin .
EUROPEAN SPINE JOURNAL, 2011, 20 (11) :1814-1820
[7]
Efficacy of anterior cervical fusion: Comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts [J].
Chou, Yu-Cheng ;
Chen, Der-Cherng ;
Hsieh, Wanhua Annie ;
Chen, Wu-Fu ;
Yen, Pao-Sheng ;
Harnod, Tomor ;
Chiou, Tsung-Lang ;
Chang, Yuh-Lin ;
Su, Chain-Fa ;
Lin, Shinn-Zong ;
Chen, Shin-Yuan .
JOURNAL OF CLINICAL NEUROSCIENCE, 2008, 15 (11) :1240-1245
[8]
Edwards WT, 2001, SPINE, V26, P218
[9]
ROBINSON ANTERIOR CERVICAL FUSION - COMPARISON OF THE STANDARD AND MODIFIED TECHNIQUES [J].
EMERY, SE ;
BOLESTA, MJ ;
BANKS, MA ;
JONES, PK .
SPINE, 1994, 19 (06) :660-663
[10]
Biomechanics of the aging spine [J].
Ferguson, SJ ;
Steffen, T .
EUROPEAN SPINE JOURNAL, 2003, 12 (Suppl 2) :S97-S103