Maximizing peak capacity and separation speed in liquid chromatography

被引:46
作者
Petersson, Patrik [1 ]
Frank, Andre [1 ]
Heaton, James [2 ]
Euerby, Melvin R. [2 ]
机构
[1] AstraZeneca R&D, S-22187 Lund, Sweden
[2] AstraZeneca, R&D Charnwood, Loughborough, Leics, England
关键词
flow rate; gradient time; sub-2 mu m particles; superficially porous particles; temperature; UPLC;
D O I
10.1002/jssc.200800064
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The practical effects of gradient time and flow rate on the peak capacities of a range of analytes of differing molecular weights (MWs) and physico-chemical properties have been evaluated using ultra high pressure LC instrumentation with sub-2 mu m and superficially porous particle phases. Optimum peak capacity, in RP gradient LC, for small molecules, including typical pharmaceutical drugs and peptides with MWs up to 1300, was demonstrated at a maximum flow rate for a given gradient time (i.e. up to 40 min). Flow rates significantly higher than the optimum in the van Deemter plots and also higher than those typically employed by the majority of the chromatographers today are recommended for gradient LC (i.e. up to 1.0 mL/min on 50 - 150 x 2.1 min 1.7 mu m columns). This recommendation is applicable for temperatures above 40 degrees C, i.e. temperatures typically utilized for separations employing sub-2 mu m particles to reduce column back pressure. Van Deemter and pseudo van Deemter plots were determined and combined with chromatographic gradient elution theory to explain our unexpected observations. The derived models exhibited good agreement between experimental and predicted peak capacities (absolute average error 4%, max. error 12%).
引用
收藏
页码:2346 / 2357
页数:12
相关论文
共 28 条
[11]  
JANDERA P, 1985, GRADIENT ELUTION COL, P112
[12]   Can the theory of gradient liquid chromatography be useful in solving practical problems? [J].
Jandera, Pavel .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1126 (1-2) :195-218
[13]   Investigating the human metabolism of acetaminophen using UPLC and exact mass oa-TOF MS [J].
Johnson, KA ;
Plumb, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) :805-810
[14]   IMPLEMENTATION AND USE OF GRADIENT PREDICTIONS FOR OPTIMIZATION OF REVERSED-PHASE LIQUID-CHROMATOGRAPHY OF PEPTIDES - PRACTICAL CONSIDERATIONS [J].
LUNDELL, N .
JOURNAL OF CHROMATOGRAPHY, 1993, 639 (02) :97-115
[15]   Theory of peak capacity in gradient elution [J].
Neue, UD .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :153-161
[16]  
Neue UD, 2001, J SEP SCI, V24, P921, DOI 10.1002/1615-9314(20011201)24:12<921::AID-JSSC921>3.0.CO
[17]  
2-2
[18]   Peak capacity in unidimensional chromatography [J].
Neue, Uwe Dieter .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) :107-130
[19]   Characterisation of RPLC columns packed with porous sub-2 μm particles [J].
Petersson, Patrik ;
Euerby, Melvin R. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (13) :2012-2024
[20]   The application of small porous particles, high temperatures, and high pressures to generate very high resolution LC and LC/MS separations [J].
Plumb, Robert ;
Mazzeo, Jeff R. ;
Grumbach, Eric S. ;
Rainville, Paul ;
Jones, Michael ;
Wheat, Tom ;
Neue, Uwe D. ;
Smith, Brian ;
Johnson, Kelly A. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (08) :1158-1166