Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter - Evaluation with a computer-simulated liver including tumors

被引:40
作者
Funama, Y
Awai, K
Miyazaki, O
Nakayama, Y
Goto, T
Omi, Y
Shimonobo, T
Liu, D
Yamashita, Y
Hori, S
机构
[1] Kumamoto Univ, Sch Hlth Sci, Dept Med Informat Syst, Kumamoto 8620976, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Kumamoto Univ Hosp, Dept Radiol, Kumamoto, Japan
[4] Hitachi Med Corp, Tokyo, Japan
[5] Gate Tower Inst Image Guided Therapy, Osaka, Japan
关键词
adaptive noise reduction filter; low-dose; low-contrast delectability; hepatic MDCT;
D O I
10.1097/01.rli.0000188026.20172.5d
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: The purpose of this study was to investigate how much radiation dose can be reduced without loss of low-contrast detectability with a newly developed adaptive noise reduction filter in hepatic multidetector computed tomography (MDCT) scans by using a computer-simulated liver phantom. Materials and Methods: Simulated CT images, including liver and intrahepatic tumors, were mathematically constructed using a computer workstation to evaluate low-contrast detectability by the observer performance test. Milliampere second for construction of simulated images were 60, 80, 100, and 120 mAs (low dose) and 160 mAs (standard dose) at 120 kVp. Images with 60, 80, 100, and 120 mAs were postprocessed with the adaptive noise reduction filter. A total of 432 images were prepared and receiver operating characteristic (ROC) analysis was performed by 5 radiologists. The detectability of simulated tumor by radiologists was estimated with the area under the ROC curves (Az values). In addition, we visually evaluated CT images of 15 patients with chronic liver damage for graininess of the liver parenchyma, sharpness of the liver contour, conspicuity and marginal sharpness of the liver tumors, and overall image quality. \ Results: The mean Az value at 0.777 (60 mAs), 0.828 (80 mAs), and 0.844 (100 mAs) without filter was significantly lower than that of 160 mAs without filter (P < 0.001, 60 mAs; P = 0.010, 80 mAs; P = 0.040, 100 mAs). There was no statistical difference between the mean Az value at 80 mAs with and 160 mAs without the adaptive noise reduction filter (P = 0.220) and 100 mAs with and 160 mAs without the adaptive noise reduction filter (P = 0.979). In the visual evaluation of patient livers, there was no statistical difference in the graininess and sharpness of the liver, the conspicuity and marginal sharpness of the tumor, and the overall image quality between standard-dose and filtered low-dose images (Wilcoxon signed rank test, P > 0.05). Conclusion: The radiation dose can be reduced by 50% without loss of nodule detectability by applying the adaptive noise reduction filter to simulated and patient liver images obtained at MDCT.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 26 条
[1]
Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique [J].
Baum, U ;
Anders, K ;
Steinbichler, G ;
Lell, M ;
Greess, H ;
Riedel, T ;
Kachelriess, M ;
Kalender, WA ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2004, 14 (10) :1873-1881
[2]
Multi-detector row CT systems and image-reconstruction techniques [J].
Flohr, TG ;
Schaller, S ;
Stierstorfer, K ;
Bruder, H ;
Ohnesorge, BM ;
Schoepf, UJ .
RADIOLOGY, 2005, 235 (03) :756-773
[3]
Multiphase hepatic CT with a multirow detector CT scanner [J].
Foley, WD ;
Mallisee, TA ;
Hohenwalter, MD ;
Wilson, CR ;
Quiroz, FA ;
Taylor, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (03) :679-685
[4]
Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients [J].
Frush, DP ;
Slack, CC ;
Hollingsworth, CL ;
Bisset, GS ;
Donnelly, LF ;
Hsieh, J ;
Lavin-Wensell, T ;
Mayo, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1107-1113
[5]
FUNAMA Y, IN PRESS EUR RADIOL
[6]
Effect of acquisition technique on radiation dose and image quality in multidetector row computed tomography coronary angiography with submillimeter collimation [J].
Gerber, TC ;
Stratmann, BP ;
Kuzo, RS ;
Kantor, B ;
Morin, RL .
INVESTIGATIVE RADIOLOGY, 2005, 40 (08) :556-563
[7]
Optimization of eight-element multi-detector row helical CT technology for evaluation of the abdomen [J].
Gupta, AK ;
Nelson, RC ;
Johnson, GA ;
Paulson, EK ;
Delong, DM ;
Yoshizumi, TT .
RADIOLOGY, 2003, 227 (03) :739-745
[8]
Multi-detector row CT: Radiation dose characteristics [J].
Hamberg, LM ;
Rhea, JT ;
Hunter, GJ ;
Thrall, JH .
RADIOLOGY, 2003, 226 (03) :762-772
[9]
A computer simulation of wavelet noise reduction in computed tomography [J].
Harpen, MD .
MEDICAL PHYSICS, 1999, 26 (08) :1600-1606
[10]
Helical CT for nephrolithiasis and ureterolithiasis: Comparison of conventional and reduced radiation-dose techniques [J].
Heneghan, JP ;
McGuire, KA ;
Leder, RA ;
DeLong, DM ;
Yoshizumi, T ;
Nelson, RC .
RADIOLOGY, 2003, 229 (02) :575-580