Assessment of hepatic perfusion parameters with dynamic MRI

被引:195
作者
Materne, R
Smith, AM
Peeters, F
Dehoux, JP
Keyeux, A
Horsmans, Y
Van Beers, BE
机构
[1] Univ Catholique Louvain, St Luc Univ Hosp, Dept Radiol, B-1200 Brussels, Belgium
[2] Univ Catholique Louvain, St Luc Univ Hosp, Expt Surg Lab, B-1200 Brussels, Belgium
[3] Univ Catholique Louvain, St Luc Univ Hosp, Nucl Med Lab, B-1200 Brussels, Belgium
[4] Univ Catholique Louvain, St Luc Univ Hosp, Lab Gastroenterol, B-1200 Brussels, Belgium
关键词
magnetic resonance imaging; liver; perfusion; gadolinium;
D O I
10.1002/mrm.10045
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Quantification of hepatic perfusion parameters greatly contributes to the assessment of liver function. The purpose of this study was to describe and validate the use of dynamic MRI for the noninvasive assessment of hepatic perfusion parameters. The signal from a fast T-1-weighted spoiled gradient-echo sequence preceded by a nonslice-selective 90 degrees pulse and a spoiler gradient was calibrated in vitro with tubes filled with various gadolinium concentrations. Dynamic images of the liver were obtained after intravenous bolus administration of 0.05 mmol/kg of Gd-DOTA in rabbits with normal liver function. Hepatic, aortic, and portal venous signal intensities were converted to Gd-DOTA concentrations according to the in vitro calibration curve and fitted with a dual-input one-compartmental model. With MRI, hepatic blood flow was 100 +/- 35 mL min(-1) 100 mL(-1), the arterial fraction 24 +/- 11%, the distribution volume 13.0 +/- 3.7%, and the mean transit time 8.9 +/- 4.1 sec. A linear relationship was observed between perfusion values obtained with MRI and with radiolabeled microspheres (r = 0.93 for hepatic blood flow [P < 0.001], r = 0.79 for arterial blood flow [P = 0.01], and r = 0.91 for portal blood flow [P < 0.001]). Our results indicate that hepatic perfusion parameters can be assessed with dynamic MRI and compartmental modeling. Magn Reson Med 47:135-142, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 46 条
[1]
Hepatic perfusion after liver transplantation:: Noninvasive measurement with dynamic single-section CT [J].
Bader, TR ;
Herneth, AM ;
Blaicher, W ;
Steininger, R ;
Mühlbacher, F ;
Lechner, G ;
Grabenwöger, F .
RADIOLOGY, 1998, 209 (01) :129-134
[2]
Measurement of liver blood volume using a macromolecular MRI contrast agent at equilibrium [J].
Blustajn, J ;
Cuenod, CA ;
Clement, O ;
Siauve, N ;
VuilleminBodaghi, V ;
Frija, G .
MAGNETIC RESONANCE IMAGING, 1997, 15 (04) :415-421
[3]
GD-DOTA - CHARACTERIZATION OF A NEW PARAMAGNETIC COMPLEX [J].
BOUSQUET, JC ;
SAINI, S ;
STARK, DD ;
HAHN, PF ;
NIGAM, M ;
WITTENBERG, J ;
FERRUCCI, JT .
RADIOLOGY, 1988, 166 (03) :693-698
[4]
Regional blood flow capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience [J].
Brix, G ;
Bahner, ML ;
Hoffmann, UJ ;
Horvath, A ;
Schreiber, W .
RADIOLOGY, 1999, 210 (01) :269-276
[5]
Canet EP, 1999, JMRI-J MAGN RESON IM, V10, P423, DOI 10.1002/(SICI)1522-2586(199909)10:3<423::AID-JMRI26>3.3.CO
[6]
2-E
[7]
Corot C, 2000, J MAGN RESON IMAGING, V11, P182, DOI 10.1002/(SICI)1522-2586(200002)11:2<182::AID-JMRI16>3.0.CO
[8]
2-5
[9]
STUDIES OF GD-DTPA RELAXIVITY AND PROTON-EXCHANGE RATES IN TISSUE [J].
DONAHUE, KM ;
BURSTEIN, D ;
MANNING, WJ ;
GRAY, ML .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :66-76
[10]
Water diffusion and exchange as they influence contrast enhancement [J].
Donahue, KM ;
Weisskoff, RM ;
Burstein, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :102-110