Analysis of nucleic acids by capillary ion-pair reversed-phase HPLC coupled to negative-ion electrospray ionization mass spectrometry

被引:101
作者
Huber, CG [1 ]
Krajete, A [1 ]
机构
[1] Leopold Franzens Univ, Inst Analyt Chem & Radiochem, A-6020 Innsbruck, Austria
关键词
D O I
10.1021/ac990378j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-pair reversed-phase high-performance liquid chromatography was successfully coupled to negative-ion electrospray ionization mass spectrometry by using 60 x 0.20 mm i.d. capillary columns packed with 2.3-mu m micropellicular, octadecylated poly(styrene/divinylbenzene) particles as stationary phase and gradients of acetonitrile in 50 mM aqueous triethylammonium bicarbonate as mobile phase. Systematic variation of the eluent composition, such as concentration of ion-pair reagent, anion in the ion-pair reagent, solution pH, and acetonitrile concentration led to the conclusion that most parameters have opposite effects on chromatographic and mass spectrometric performances. The use of acetonitrile as sheath liquid enabled the rapid and highly efficient separation and detection of phosphorylated and nonphosphorylated oligonucleotides ranging in size from 8 to 40 nucleotides. High-quality full-scan mass spectra showing little cation adduction were acquired from which the molecular masses of the separated oligonucleotides were calculated with an accuracy of 0.011%. With calibration curves being linear over at least 2 orders of magnitude, the lower limits of detection for a oligodeoxythymidine 16-mer were 104 fmol with full scan and 710 amol with selected-ion-monitoring data acquisition. The potential of ion-pair reversed-phase high-performance liquid chromatography-electrospray ionization mass spectrometry was demonstrated for mixed-sequence oligomers by the characterization of a reaction mixture from solid-phase synthesis of a 40-mer oligonucleotide.
引用
收藏
页码:3730 / 3739
页数:10
相关论文
共 41 条
[11]   CHROMATOGRAPHIC-SEPARATION OF DNA RESTRICTION FRAGMENTS [J].
HECKER, R ;
RIESNER, D .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 418 :97-114
[12]   TECHNIQUES OF CAPILLARY LIQUID-CHROMATOGRAPHY [J].
HIRATA, Y ;
NOVOTNY, M .
JOURNAL OF CHROMATOGRAPHY, 1979, 186 (DEC) :521-528
[13]   On line cation exchange for suppression of adduct formation in negative-ion electrospray mass spectrometry of nucleic acids [J].
Huber, CG ;
Buchmeiser, MR .
ANALYTICAL CHEMISTRY, 1998, 70 (24) :5288-5295
[14]  
Huber CG, 1996, LC GC N AM, V14, P114
[15]   RAPID ANALYSIS OF BIOPOLYMERS ON MODIFIED NONPOROUS POLYSTYRENE - DIVINYLBENZENE PARTICLES [J].
HUBER, CG ;
OEFNER, PJ ;
BONN, GK .
CHROMATOGRAPHIA, 1993, 37 (11-12) :653-656
[16]   HIGH-RESOLUTION LIQUID-CHROMATOGRAPHY OF OLIGONUCLEOTIDES ON NONPOROUS ALKYLATED STYRENE-DIVINYLBENZENE COPOLYMERS [J].
HUBER, CG ;
OEFNER, PJ ;
BONN, GK .
ANALYTICAL BIOCHEMISTRY, 1993, 212 (02) :351-358
[17]   HIGH-RESOLUTION LIQUID-CHROMATOGRAPHY OF DNA FRAGMENTS ON NONPOROUS POLY(STYRENE-DIVINYLBENZENE) PARTICLES [J].
HUBER, CG ;
OEFNER, PJ ;
PREUSS, E ;
BONN, GK .
NUCLEIC ACIDS RESEARCH, 1993, 21 (05) :1061-1066
[18]   Micropellicular stationary phases for high-performance liquid chromatography of double-stranded DNA [J].
Huber, CG .
JOURNAL OF CHROMATOGRAPHY A, 1998, 806 (01) :3-30
[19]   RAPID AND ACCURATE SIZING OF DNA FRAGMENTS BY ION-PAIR CHROMATOGRAPHY ON ALKYLATED NONPOROUS POLY(STYRENE-DIVINYLBENZENE) PARTICLES [J].
HUBER, CG ;
OEFNER, PJ ;
BONN, GK .
ANALYTICAL CHEMISTRY, 1995, 67 (03) :578-585
[20]   HIGH-RESOLUTION SEPARATIONS BASED ON ELECTROPHORESIS AND ELECTROOSMOSIS [J].
JORGENSON, JW ;
LUKACS, KD .