Influence of measuring conditions on the quantification of spectroscopic signals in TA-FTIR-MS systems

被引:15
作者
Eigenmann, F [1 ]
Maciejewski, M [1 ]
Baiker, A [1 ]
机构
[1] ETH Honggerberg, Swiss Fed Inst Technol, Dept Chem & Appl Biosci, CH-8093 Zurich, Switzerland
关键词
calibration techniques; hyphenated techniques; pulse TA combined with FTIR; quantitative evolved gas analysis; TA-FTIR-MS;
D O I
10.1007/s10973-005-7387-z
中图分类号
O414.1 [热力学];
学科分类号
摘要
Simultaneous thermal analysis (TA) and evolved gas analysis by mass spectrometry (MS) and/or Fourier transform infrared spectroscopy (FTIR) is a powerful hyphenated technique combining direct measurement of mass loss and sensitive spectroscopic analysis. In the present study the influence of several experimental parameters which may affect the quantification of FTIR signals have been studied using a combined TA-FTIR-MS system. Parameters studied include: sample mass (1-400 mg), carrier gas flow rate (25-200 mL min(-1)), resolution of the FTIR spectrometer (1-32 cm(-1)), and location of injection of the calibrating gas. MS analysis, which was not significantly affected by the experimental conditions, was used as a reference for assessing the accuracy of quantification by FTIR. The quantification of the spectroscopic signals was verified by the decomposition (NaHCO3) or dehydration (CuSO4 center dot 5H(2)O) of compounds with well-known stoichiometry. The systematic study of the parametric sensitivity revealed that spectral resolution and carrier gas flow rate, which affect the acquisition time in the IR-cell, are key parameters that must be adjusted carefully for reliable quantification. The dependence of the reliability of quantification on these parameters is illustrated and conditions leading to proper quantification are discussed. As an example, for a standard spectral resolution of 4 cm(-1) and a FTIR gas cell volume of 8.7 mL, the carrier gas flow must be lower than 100 mL min(-1) for warranting accurate results (relative deviation < 2%). The concentration range of analyzed species is limited but can be extended by proper selection of the wavenumber regions for molecules giving strong IR signals.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 24 条
[1]   The effect of a curing agent on the thermal degradation of fire retardant brominated epoxy resins [J].
Balabanovich, AI ;
Hornung, A ;
Merz, D ;
Seffert, H .
POLYMER DEGRADATION AND STABILITY, 2004, 85 (01) :713-723
[2]   The use of TG-FTIR technique for the assessment of hydrogen bromide emissions in the combustion of BFRs [J].
Barontini, F ;
Marsanich, K ;
Cozzani, V .
JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2004, 78 (02) :599-619
[3]   TG-FTIR analysis of biomass pyrolysis [J].
Bassilakis, R ;
Carangelo, RM ;
Wójtowicz, MA .
FUEL, 2001, 80 (12) :1765-1786
[4]   QUANTITATIVE-ANALYSIS OF N-METHYL-2-PYRROLIDINONE IN COAL EXTRACTS BY TGA-FTIR [J].
CAI, MF ;
SMART, RB .
ENERGY & FUELS, 1993, 7 (01) :52-56
[5]   Selective reduction of NO by NH3 over manganese-cerium mixed oxides:: Relation between adsorption, redox and catalytic behavior [J].
Eigenmann, F ;
Maciejewski, M ;
Baiker, A .
APPLIED CATALYSIS B-ENVIRONMENTAL, 2006, 62 (3-4) :311-318
[6]   Quantitative calibration of spectroscopic signals in combined TG-FTIR system [J].
Eigenmann, F ;
Maciejewski, A ;
Baiker, A .
THERMOCHIMICA ACTA, 2006, 440 (01) :81-92
[7]   Gas adsorption studied by pulse thermal analysis [J].
Eigenmann, F ;
Maciejewski, M ;
Baiker, A .
THERMOCHIMICA ACTA, 2000, 359 (02) :131-141
[8]  
EIGENMANN F, 2000, P 3 SKT 2000 NETZSCH, P183
[9]   The thermogravimetric analyser-coupled-Fourier transform infrared mass spectrometry technique [J].
Groenewoud, WM ;
deJong, W .
THERMOCHIMICA ACTA, 1996, 286 (02) :341-354
[10]   The use of reduced pressure to expand the capabilities of TGA-FTIR [J].
Jackson, RS ;
Rager, A .
THERMOCHIMICA ACTA, 2001, 367 :415-424