β-Cyclodextrin incorporated carbon nanotube-modified electrode as an electrochemical sensor for rutin

被引:119
作者
He, JL
Yang, Y
Yang, X
Liu, YL
Liu, ZH
Shen, GL
Yu, RQ [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, State Key Lab Chemo Biosensing & Chemometr, Changsha 410082, Peoples R China
[2] Beijing Inst Pharmacol & Toxicol, Beijing 100850, Peoples R China
基金
中国国家自然科学基金;
关键词
rutin; beta-cyclodextrin; multi-walled carbon nanotubes; cyclic voltammetry;
D O I
10.1016/j.snb.2005.04.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor modified with multi-walled carbon nanotubes/beta-cyclodextrin (MWNTs/beta-CD) film was fabricated for the determination of rutin. The electrochemical behavior of rutin at the chemically modified electrode was investigated by cyclic voltammetry (CV). The response mechanism of MWNTs/beta-CD film for rutin was based on the inclusion interaction of P-CD for rutin. The MWNTs/beta-CD film showed preferably analytical performance characteristics in electrocatalytic oxidation and reduction for rutin compared with the MWNTs film and bare glassy carbon electrode (GCE). A linear calibration plot was obtained covering the range from 4.0 x 10(-7) to 1.0 x 10(-3) mol L-1 with a detection limit of 2.0 x 10(-7) mol L-1. This electrochemical sensor showed excellent sensitivity, selectivity, stability and recovery for the determination of rutin in urine samples. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 33 条
[21]   Glucose biosensor prepared by glucose oxidase encapsulated sol-gel and carbon-nanotube-modified basal plane pyrolytic graphite electrode [J].
Salimi, A ;
Compton, RG ;
Hallaj, R .
ANALYTICAL BIOCHEMISTRY, 2004, 333 (01) :49-56
[22]   Mechanical properties of carbon nanotubes [J].
Salvetat, JP ;
Bonard, JM ;
Thomson, NH ;
Kulik, AJ ;
Forró, L ;
Benoit, W ;
Zuppiroli, L .
APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1999, 69 (03) :255-260
[23]   Sensitive determination of sub-nanogram amounts of rutin by its inhibition on chemiluminescence with immobilized reagents [J].
Song, ZH ;
Hou, S .
TALANTA, 2002, 57 (01) :59-67
[24]  
Sun W.Q., 1998, HDB NATURAL ACTIVE C, P2240
[25]   Functionalized carbon nanotubes: Properties and applications [J].
Sun, YP ;
Fu, KF ;
Lin, Y ;
Huang, WJ .
ACCOUNTS OF CHEMICAL RESEARCH, 2002, 35 (12) :1096-1104
[26]   Carbon nanotubes as electrode materials for the assembling of new electrochemical biosensors [J].
Valentini, F ;
Orlanducci, S ;
Terranova, ML ;
Amine, A ;
Palleschi, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 100 (1-2) :117-125
[27]   Determination of rutin and other flavonoids by flow-injection/adsorptive stripping voltammetry using nujol-graphite and diphenylether-graphite paste electrodes [J].
Volikakis, GJ ;
Efstathiou, CE .
TALANTA, 2000, 51 (04) :775-785
[28]   Electrocatalytic response of norepinephrine at a β-cyclodextrin incorporated carbon nanotube modified electrode [J].
Wang, GY ;
Liu, XJ ;
Yu, B ;
Luo, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 567 (02) :227-231
[29]   Electrochemical detection of trace insulin at carbon-nanotube-modified electrodes [J].
Wang, J ;
Musameh, M .
ANALYTICA CHIMICA ACTA, 2004, 511 (01) :33-36
[30]   Carbon nanotube-modified glassy carbon electrode for adsorptive stripping voltammetric detection of ultratrace levels of 2,4,6-trinitrotoluene [J].
Wang, J ;