Separation and detection of nitrophenols at capillary electrophoresis microchips with amperometric detection

被引:66
作者
Fischer, J
Barek, J
Wang, J [1 ]
机构
[1] Arizona State Univ, Dept Chem & Mat Engn, Biodesign Inst, Tempe, AZ 85287 USA
[2] Arizona State Univ, Dept Chem & Biochem, Biodesign Inst, Tempe, AZ 85287 USA
[3] Charles Univ, Dept Analyt Chem, UNESCO Lab Environm Electrochem, Prague 12843 2, Czech Republic
关键词
nitrophenols; capillary electrophoresis; micromachining; microchip; amperometric detection;
D O I
10.1002/elan.200503393
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A Miniaturized analytical system for the separation and amperometric detection of toxic nitrophenols, based on the Coupling of a micromachined capillary electrophoresis (CE) chip with a glassy carbon detector is described. This microsystem enables a rapid (120 s/sample) simultancous determination of five priority nitrophenolic Pollutants (2-nitrophenol, 3-nitrophenol, 4-nitrophenol, 2,4-dinitrophenol, and 2-methyl-4,6-dinitrophenol). These compounds can be detected down to the 1 x 10(-5) M level using a 15 mM phosphate buffer pH 7.2 (containing 1.3 mM alpha-cyclodextrin) as running solution on 77 mm long microchannel by applying a separation voltage of 3000 V and a negative potential of -0.7 V (vs. Ag/AgCl wire). Applicability to ground water samples was demonstrated.
引用
收藏
页码:195 / 199
页数:5
相关论文
共 23 条
[1]  
[Anonymous], 1992, TOX PROF NITR
[2]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[3]   Counting single chromophore molecules for ultrasensitive analysis and separations on microchip devices [J].
Fister, JC ;
Jacobson, SC ;
Davis, LM ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1998, 70 (03) :431-437
[4]   The separation and determination of nitrophenol isomers by high-performance capillary zone electrophoresis [J].
Guo, XF ;
Wang, ZH ;
Zhou, SP .
TALANTA, 2004, 64 (01) :135-139
[5]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[6]   PREPARATION OF AN ELECTRODE SURFACE WITH A HIGH-DENSITY OF BINDING-SITES BY AN ELECTROCHEMICAL REDUCTION OF A POLY(NITROPHENOL) FILM [J].
HEIDUSCHKA, P ;
SCHELLER, FW .
BIOSENSORS & BIOELECTRONICS, 1994, 9 (03) :R7-R9
[7]   Ceramic microchips for capillary electrophoresis-electrochemistry [J].
Henry, CS ;
Zhong, M ;
Lunte, SM ;
Kim, M ;
Bau, H ;
Santiago, JJ .
ANALYTICAL COMMUNICATIONS, 1999, 36 (08) :305-307
[8]   Cathodic electrochemical detection of nitrophenols at a bismuth film electrode for use in flow analysis [J].
Hutton, EA ;
Ogorevc, B ;
Smyth, MR .
ELECTROANALYSIS, 2004, 16 (19) :1616-1621
[9]   SEPARATION OF PRIORITY POLLUTANT PHENOLS ON CHEMICALLY-MODIFIED POLY(STYRENE-DIVINYLBENZENE) RESINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
KLAMPFL, CW ;
SPANOS, E .
JOURNAL OF CHROMATOGRAPHY A, 1995, 715 (02) :213-218
[10]   Integration of microfabricated devices to capillary electrophoresis-electrospray mass spectrometry using a low dead volume connection: Application to rapid analyses of proteolytic digests [J].
Li, JJ ;
Thibault, P ;
Bings, NH ;
Skinner, CD ;
Wang, C ;
Colyer, C ;
Harrison, J .
ANALYTICAL CHEMISTRY, 1999, 71 (15) :3036-3045