CHIP-MASS SPECTROMETRY FOR GLYCOMIC STUDIES

被引:24
作者
Bindila, Laura [1 ]
Peter-Katalinic, Jasna [1 ]
机构
[1] Univ Munster, Inst Med Phys & Biophys, D-48149 Munster, Germany
关键词
chip-mass spectrometry; micro-total analysis device; hyphenated-mass spectrometry; carbohydrates; glycomics; ELECTRON-CAPTURE DISSOCIATION; HUMAN BLOOD-SERUM; CAPILLARY-ELECTROPHORESIS; HIGH-SENSITIVITY; STRUCTURAL-CHARACTERIZATION; O-GLYCOSYLATION; GLYCOCONJUGATE ANALYSIS; FLUORESCENCE DETECTION; MICROFLUIDIC DEVICES; POLYMER MICROSPRAY;
D O I
10.1002/mas.20197
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The introduction of micro- and nanochip front end technologies for electrospray, mass spectrometry addressed a major challenge in carbohydrate analysis: high sensitivity structural determination and heterogeneity assessment in high dynamic range mixtures of biological origin. Chip-enhanced electrospray ionization was demonstrated to provide reproducible performance irrespective of the type of carbohydrate, while the amenability of chip systems for coupling with different mass spectrometers greatly advance the chip/MS technique as a versatile key tool in glycomic studies. A more accurate representation of the glycan repertoire to include novel biologically-relevant information was achieved in different biological sources, asserting this technique as a valuable tool in glycan biomarker discovery and monitoring. Additionally, the integration of various analytical functions onto chip devices and direct hyphenation to MS proved its potential for glycan analysis during the recent Years, where by a new analytical tool is on the verge of maturation: lab-on-chip MS glycomics. The achievements until early beginning of 2007 on the implementation of chip- and functional integrated chip/MS in systems glyco-biology studies are reviewed here. (C) 2009 Wiley Periodicals, Inc., Mass Spec Rev 29:223-253, 2009
引用
收藏
页码:223 / 253
页数:31
相关论文
共 96 条
[91]   Recent advances in sheathless interfacing of capillary electrophoresis and electrospray ionization mass spectrometry [J].
Zamfir, Alina D. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) :2-13
[92]   Automated chip-based nanoelectrospray-mass spectrometry for rapid identification of proteins separated by two-dimensional gel electrophoresis [J].
Zhang, S ;
Van Pelt, CK ;
Henion, JD .
ELECTROPHORESIS, 2003, 24 (21) :3620-3632
[93]   Quantitative determination of noncovalent binding interactions using automated nanoelectrospray mass spectrometry [J].
Zhang, S ;
Van Pelt, CK ;
Wilson, DB .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3010-3018
[94]  
Zhang Sheng, 2005, J Biomol Tech, V16, P209
[95]  
Zhang Sheng, 2004, J Biomol Tech, V15, P120
[96]   Chip-based CE coupled to a quadrupole TOF mass spectrometer for the analysis of a glycopeptide [J].
Zheng, Yufang ;
Li, Haifang ;
Guo, Zhihong ;
Lin, Jin-Ming ;
Cai, Zongwei .
ELECTROPHORESIS, 2007, 28 (09) :1305-1311