Dual time point fluorine-18 fluorodeoxyglucose positron emission tomography: a potential method to differentiate malignancy from inflammation and normal tissue in the head and neck

被引:238
作者
Hustinx, R
Smith, RJ
Benard, F
Rosenthal, DI
Machtay, M
Farber, LA
Alavi, A
机构
[1] Hosp Univ Penn, Div Nucl Med, Philadelphia, PA 19104 USA
[2] Univ Penn Hlth Syst, Dept Radiat Oncol, Philadelphia, PA USA
基金
英国医学研究理事会;
关键词
positron emission tomography; fluorine-18; fluorodeoxyglucose; head and neck cancer; inflammation; standardised uptake value;
D O I
10.1007/s002590050593
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) studies imaging FDG PET imaging is used to detect and stage head and neck cancers. However, the variable physiologic uptake of FDG in different normal structures as well as at inflammatory sites may either obscure a tumor focus or be falsely interpreted to represent tumor activity, Twenty-one patients (9 men, 12 women, median age 59) were scanned serially at two time points, one at 70 min (range 47-112) and the second at 98 min (77-142) after the intravenous injection of 4.3 MBq/kg of FDG. The mean interval between emission scans was 28 min (13-49). Transmission scans were performed and regions of interest (ROIs) were overlayed on the fully corrected images. Standardiued uptake values (SUVs) were generated for the cerebellum, tongue, larynx, every lesion, and a matched contralateral site. Follow-up and pathologic studies revealed 18 squamous cell carcinomas and nine inflammatory or infectious lesions. Tumor SUVs were 4.0+/-1.6 (mean +/- SD) for the first scan and 4.5+/-2.2 for the second scan. Contralateral SUVs were 1.2+/-0.5 and 1.1+/-0.5 for the two scans. Tumor SUVs increased by 12%+/-12% as compared with a 5%+/-17% decrease for contralateral sites (P<0.05). SUVs for inflammatory sites (2.0+/-0.7 and 2.0+/-0.9), cerebellum (4.2+/-1.3 and 4.3+/-1.4), tongue (1.8+/-0.4 and 1.9+/-0.5) and larynx (1.5+/-0.6 and 1.5+/-0.6) remained constant over time (+0.6%, +2.8%, +1.4%, and -2.4%; P<0.05 when compared with tumor SUV changes). The ratio tumor/contralateral SUV increased by 23%+/-29% over time while this ratio for inflamed sites increased by only 5%+/-15% (P=0.07). The time interval between scans correlated with increase in SUV for tumors (r=0.55, P<0.05) but not for any of the other ROIs. Separation was superior when studies were performed more than 30 min apart (P<0.05). These preliminary data suggest that dual time point imaging compatible with a clinical study protocol is helpful in differentiating malignant lesions from inflammation and normal tissues, especially when separated by a sufficient time interval.
引用
收藏
页码:1345 / 1348
页数:4
相关论文
共 10 条
[1]  
FISCHMAN AJ, 1993, J NUCL MED, V34, P6
[2]  
HAMBERG LM, 1994, J NUCL MED, V35, P1308
[3]   EFFECT OF INCREASED AXIAL-FIELD OF VIEW ON THE PERFORMANCE OF A VOLUME PET SCANNER [J].
KARP, JS ;
KINAHAN, PE ;
MUEHLLEHNER, G ;
COUNTRYMAN, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :299-306
[4]   A PET study of 18FDG uptake in soft tissue masses [J].
Lodge, MA ;
Lucas, JD ;
Marsden, PK ;
Cronin, BF ;
O'Doherty, MJ ;
Smith, MA .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (01) :22-30
[5]   ACCELERATED EM RECONSTRUCTION IN TOTAL-BODY PET - POTENTIAL FOR IMPROVING TUMOR DETECTABILITY [J].
MEIKLE, SR ;
HUTTON, BF ;
BAILEY, DL ;
HOOPER, PK ;
FULHAM, MJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (10) :1689-1704
[6]   18FDG-PET for the assessment of primary head and neck tumors:: Clinical, computed tomography, and histopathological correlation in 38 patients [J].
Paulus, P ;
Sambon, A ;
Vivegnis, D ;
Hustinx, R ;
Moreau, P ;
Collignon, J ;
Deneufbourg, JM ;
Rigo, P .
LARYNGOSCOPE, 1998, 108 (10) :1578-1583
[7]   Oncological applications of positron emission tomography with fluorine-18 fluorodeoxyglucose [J].
Rigo, P ;
Paulus, P ;
Kaschten, BJ ;
Hustinx, R ;
Bury, T ;
Jerusalem, G ;
Benoit, T ;
FoidartWillems, J .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (12) :1641-1674
[8]   Singles transmission scans performed post-injection for quantitative whole body PET imaging [J].
Smith, RJ ;
Karp, JS ;
Muehllehner, G ;
Gualtieri, E ;
Benard, F .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :1329-1335
[9]   A comparison of segmentation and emission subtraction for singles transmission in PET. [J].
Smith, RJ ;
Karp, JS ;
Benard, F ;
Alavi, A ;
Gualtieri, E ;
Muehllehner, G ;
Geagan, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) :1212-1218
[10]   Fluorine-18 deoxyglucose and false-positive results: A major problem in the diagnostics of oncological patients [J].
Strauss, LG .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (10) :1409-1415