A comparison of segmentation and emission subtraction for singles transmission in PET.

被引:18
作者
Smith, RJ
Karp, JS
Benard, F
Alavi, A
Gualtieri, E
Muehllehner, G
Geagan, M
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[2] UGM Med Syst, Philadelphia, PA 19104 USA
关键词
D O I
10.1109/23.682005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Single photon transmission scans, using Cs-137 (662 keV gamma rays), are performed past-injection for clinical whole body PET studies. Two methods of processing the transmission data are investigated. The first method segments the transmission image into lung and soft tissue volumes. Average attenuation coefficients for 511 keV are applied and this transmission image is forward projected for attenuation correction. In the second method short emission contamination (EC) scans are performed after the singles transmission scans. These are singles transmission scans without a Cs-137 transmission source. These EC scans are then subtracted from the transmission scans to remove contamination of the 662 keV energy window by 511 keV emission gamma rays, From ten patients studied by this method, the EC subtracted transmission images have average soft tissue attenuation coefficients of 0.074/cm, compared to the expected value of 0.086/cm for 662 keV gamma rays. Simple scaling of these transmission images to 511 keV values (0.095/cm) results in quantitative attenuation correction. A comparison of the two methods is made for these ten patient studies. Both methods result in accurate attenuation correction. The segmentation method performs low noise attenuation correction but is more limited to torso studies with the limbs out of the FOV. The EC subtraction method is more versatile and is applicable to the entire body but results in some more noise in the fully corrected images.
引用
收藏
页码:1212 / 1218
页数:7
相关论文
共 19 条
[1]  
BAILEY DL, 1997, J NUCL MED, V38, P113
[2]  
CHATZIIOANNOU A, 1996, J NUCL MED, V37, P8
[3]   POST-INJECTION TRANSMISSION ATTENUATION MEASUREMENTS FOR PET [J].
DAUBEWITHERSPOON, ME ;
CARSON, RE ;
GREEN, MV .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :757-761
[4]   ATTENUATION CORRECTION IN PET USING SINGLE-PHOTON TRANSMISSION MEASUREMENT [J].
DEKEMP, RA ;
NAHMIAS, C .
MEDICAL PHYSICS, 1994, 21 (06) :771-778
[5]  
HUDSON HM, 1994, IEEE T MED IMAGING, V13, P61
[6]  
ICHIYA Y, 1991, J NUCL MED, V32, P1655
[7]  
KARP JS, 1990, J NUCL MED, V31, P617
[8]   SINGLES TRANSMISSION IN VOLUME-IMAGING PET WITH A CS-137 SOURCE [J].
KARP, JS ;
MUEHLLEHNER, G ;
QU, H ;
YAN, XH .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (05) :929-944
[9]   EFFECT OF INCREASED AXIAL-FIELD OF VIEW ON THE PERFORMANCE OF A VOLUME PET SCANNER [J].
KARP, JS ;
KINAHAN, PE ;
MUEHLLEHNER, G ;
COUNTRYMAN, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (02) :299-306
[10]  
KARP JS, 1995, P IEEE T MED IM C SA, V3, P1363