Optimization of a contrast-detail-based method for electronic image display quality evaluation

被引:10
作者
Hangiandreou, NJ [1 ]
Fetterly, KA [1 ]
Felmlee, JP [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Diagnost Radiol, Rochester, MN 55905 USA
关键词
contrast-detail experiments; electronic image display; image quality evaluation;
D O I
10.1007/BF03168844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors previously reported a general technique based on contrast-detail methods to provide an overall quantitative evaluation of electronic image display quality. The figure-of-merit reflecting overall display quality is called maximum threshold contrast or MTC. In this work we have optimized the MTC technique through improvements in both the test images and the figure-of-merit computation. The test images were altered to match the average luminance with that observed for clinical computed radiographic images. The figure-of-merit calculation was altered to allow for contrast-detail data with slopes not equal to -1. Preliminary experiments also were conducted to demonstrate the response of the MTC measurements to increased noise in the displayed image. MTC measurements were obtained from five observers using the improved test images displayed with maximum monitor luminance settings of 30-, 50-, and 70-ft-Lamberts. Similar measurements were obtained from two observers using test images altered by the addition of a low level of image noise. The noise-free MTC and MTC difference measurements exhibited standard deviations of 0.77 and 1.55, respectively. This indicates good measurement precision, comparable or superior to that observed using the earlier MTC technique. No statistically significant image quality differences versus maximum monitor luminance were seen. The noise-added MTC measurements were greater than the noise-free values by an average of 4.08 pixel values, and this difference was statistically significant. This response is qualitatively correct, and is judged to indicate good sensitivity of the MTC measurement to increased noise levels. Copyright (C) 1999 by W.B. Saunders Company.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 16 条
[1]   The ACR/NEMA proposal for a grey-scale display function standard [J].
Blume, H .
IMAGE DISPLAY: MEDICAL IMAGING 1996, 1996, 2707 :344-360
[2]   ANALYSIS OF VARIATIONS IN CONTRAST-DETAIL EXPERIMENTS [J].
COHEN, G ;
MCDANIEL, DL ;
WAGNER, LK .
MEDICAL PHYSICS, 1984, 11 (04) :469-473
[3]   USE OF CONTRAST-DETAIL-DOSE EVALUATION OF IMAGE QUALITY IN A COMPUTED TOMOGRAPHIC SCANNER [J].
COHEN, G ;
DIBIANCA, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) :189-195
[4]   CONTRAST, RESOLUTION, AND DETECTABILITY IN MR IMAGING [J].
CONSTABLE, RT ;
HENKELMAN, RM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (02) :297-303
[5]   Comparison of a cathode-ray-tube and film for display of computed radiographic images [J].
Cook, LT ;
Cox, GG ;
Insana, MF ;
McFadden, MA ;
Hall, TJ ;
Gaborski, RS ;
Lure, FYM .
MEDICAL PHYSICS, 1998, 25 (07) :1132-1138
[6]   THRESHOLD PERCEPTION PERFORMANCE WITH COMPUTED AND SCREEN-FILM RADIOGRAPHY - IMPLICATIONS FOR CHEST RADIOGRAPHY [J].
DOBBINS, JT ;
RICE, JJ ;
BEAM, CA ;
RAVIN, CE .
RADIOLOGY, 1992, 183 (01) :179-187
[7]   Picture archive and communication systems implementation in a community medicine practice [J].
Hangiandreou, NJ ;
King, BF ;
Swenson, AR ;
Webbles, WE ;
Jorgenson, LL .
JOURNAL OF DIGITAL IMAGING, 1997, 10 (03) :36-37
[8]   Quantitative evaluation of overall electronic display quality [J].
Hangiandreou, NJ ;
Fetterly, KA ;
Bernatz, SN ;
Cesar, LJ ;
Groth, DS ;
Felmlee, JP .
JOURNAL OF DIGITAL IMAGING, 1998, 11 (03) :180-186
[9]   OBSERVER PERFORMANCE COMPARISON OF DIGITAL RADIOGRAPH SYSTEMS FOR STEREOTAXIC BREAST NEEDLE-BIOPSY [J].
KRUPINSKI, EA ;
ROEHRIG, H ;
YU, T .
ACADEMIC RADIOLOGY, 1995, 2 (02) :116-122
[10]   A comprehensive physical image quality evaluation of a selenium based digital x-ray imaging system for thorax radiography [J].
Launders, JH ;
Kengyelics, SM ;
Cowen, AR .
MEDICAL PHYSICS, 1998, 25 (06) :986-997