Automatic detection of distorted plethysmogram pulses in neonates and paediatric patients using an adaptive-network-based fuzzy inference system

被引:50
作者
Belal, SY
Taktak, AFG
Nevill, AJ
Spencer, SA
Roden, D
Bevan, S
机构
[1] Keele Univ, Ctr Sci & Technol Med, Dept Biomed Engn & Med Phys, Stoke On Trent ST4 7QB, Staffs, England
[2] N Staffordshire Hosp, NHS Trust, Clin Technol Dept, Stoke On Trent ST4 6QG, Staffs, England
[3] Women & Childrens Div, Matern Unit, Stoke On Trent ST4 6QG, Staffs, England
关键词
adaptive-network-based fuzzy inference system; artefact detection; oxygen saturation false alarms; plethysmogram; pulse oximetry; neonates; paediatrics;
D O I
10.1016/S0933-3657(01)00099-9
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Despite the fact that pulse oximetry has become an essential technology in respiratory monitoring of neonates and paediatric patients, it is still fraught with artefacts causing false alarms resulting from patient or probe movement. As the shape of the plethysmogram has always been considered as a useful visual indicator for determining the reliability of SaO(2) numerical readings, automation of this observation might benefit health care providers at the bedside. We observed that the systolic upstroke time (t(1)), the diastolic time (t(2)) and heart rate (HR) extracted from the plethysmogram pulse constitute features, which can be used for detecting normal and distorted plethysmogram pulses. We developed a technique for classifying plethysmogram pulses into two categories: valid and artefact via implementations of fuzzy inference systems (FIS), which were tuned using an adaptive-network-based fuzzy inference system (ANFIS) and receiver operating characteristics (ROC) curves analysis. Features extracted from a total of 22,497 pulse waveforms obtained from 13 patients were used to systematically optimise the FIS. A further 2843 waveforms obtained from another eight patients were used for testing the system, and visually classified into 1635 (58%) valid and 1208 (42%) distorted segments. For the optimum system, the area under the ROC curve was 0.92. The system was able to classify 1418 (87%) valid segments and 897 (74%) distorted segments correctly. The calculations of the system's performance showed 87% sensitivity, 81% accuracy and 74% specificity. In comparison with the 95% confidence interval (CI) thresholding method, the fuzzy system showed higher specificity (P = 0.008, P < 0.01), and no significant difference was found between the two methods in terms of sensitivity (P = 0.720, P > 0.05) and accuracy (P = 0.053, P > 0.05). We therefore conclude that the algorithm used in this system has some potential in detecting valid and distorted plethysmogram pulse. However, further evaluation is needed using larger patient groups. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:149 / 165
页数:17
相关论文
共 37 条
[1]   A COMPUTER ALGORITHM FOR DIFFERENTIATING VALID FROM DISTORTED PULSE OXIMETER WAVE-FORMS IN NEONATES [J].
ADAMS, JA ;
INMAN, IM ;
ABREU, SA ;
ZABALETA, IA ;
SACKNER, MA .
PEDIATRIC PULMONOLOGY, 1995, 19 (05) :307-311
[2]  
[Anonymous], INT J APPROXIMATE RE
[3]  
ARAKI S, 1992, P INT FUZZ ENG S IFE, P1047
[4]   A fuzzy system for detecting distorted plethysmogram pulses in neonates and paediatric patients [J].
Belal, SY ;
Taktak, AFG ;
Nevill, AJ ;
Spencer, SA .
PHYSIOLOGICAL MEASUREMENT, 2001, 22 (02) :397-412
[5]   LEARNING AND TUNING FUZZY-LOGIC CONTROLLERS THROUGH REINFORCEMENTS [J].
BERENJI, HR ;
KHEDKAR, P .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1992, 3 (05) :724-740
[6]  
CUNNINGHAM S, 1997, INT J CLIN MONIT COM, V13, P235
[7]   PULSE OXIMETRY FOR CONTINUOUS OXYGEN MONITORING IN SICK NEWBORN-INFANTS [J].
DURAND, M ;
RAMANATHAN, R .
JOURNAL OF PEDIATRICS, 1986, 109 (06) :1052-1056
[8]   PULSE OXIMETRY IN PEDIATRIC INTENSIVE-CARE - COMPARISON WITH MEASURED SATURATIONS AND TRANS-CUTANEOUS OXYGEN-TENSION [J].
FANCONI, S ;
DOHERTY, P ;
EDMONDS, JF ;
BARKER, GA ;
BOHN, DJ .
JOURNAL OF PEDIATRICS, 1985, 107 (03) :362-366
[9]   Comparison of two different pulse oximeters in monitoring preterm infants [J].
Grieve, SH ;
McIntosh, N ;
Laing, IA .
CRITICAL CARE MEDICINE, 1997, 25 (12) :2051-2054
[10]   NEURAL NETWORKS IN DESIGNING FUZZY-SYSTEMS FOR REAL-WORLD APPLICATIONS [J].
HALGAMUGE, SK ;
GLESNER, M .
FUZZY SETS AND SYSTEMS, 1994, 65 (01) :1-12