A fuzzy system for detecting distorted plethysmogram pulses in neonates and paediatric patients

被引:3
作者
Belal, SY
Taktak, AFG
Nevill, AJ
Spencer, SA
机构
[1] Keele Univ, Ctr Sci & Technol Med, Stoke On Trent ST4 7QB, Staffs, England
[2] N Staffordshire Hosp, Stoke On Trent ST4 7QB, Staffs, England
关键词
pulse oximetry; artefact detection; fuzzy logic;
D O I
10.1088/0967-3334/22/2/311
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Pulse oximetry is a useful, quick, non-invasive and widely used technology for monitoring oxygen saturation (SaO(2)) for neonates and paediatric patients. However, pulse oximetry is fraught with artefacts, causing false alarms resulting from patient or probe movement. The shape of the plethysmogram is a useful visual indicator for determining the reliability of SaO(2) numerical readings. If certain features could be defined that tag valid plethysmogram pulses, then automatic recognition of valid SaO(2) values can be attained. We observed that the systolic upstroke time (t(1)), the diastolic time (t(2)) and heart rate (HR) extracted from the plethysmogram pulse constitute features which can be used for detecting normal and distorted plethysmogram pulses. Therefore, we developed a knowledge-based system using fuzzy logic for classifying plethysmogram pulses into two categories: valid and artefact. A total of 22497 pulse waveforms were used to define the system parameters. These were obtained from 13 patients with heart rates ranging between 62 and 209 beats min(-1). A further 1420 waveforms obtained from another four patients were used for testing the system, and visually classified into 833 (59%) valid and 587 (41%) distorted segments. The system was able to classify 679 (82%) valid segments and 543 (93%) distorted segments correctly. The calculations of the system's performance showed 82% sensitivity, 86% accuracy and 93% specificity. We, therefore, conclude that the algorithm used in this system can he implemented in its present form for real-time SaO(2) monitoring in intensive care for detecting valid and distorted plethysmogram pulses.
引用
收藏
页码:397 / 412
页数:16
相关论文
共 29 条
[1]   A COMPUTER ALGORITHM FOR DIFFERENTIATING VALID FROM DISTORTED PULSE OXIMETER WAVE-FORMS IN NEONATES [J].
ADAMS, JA ;
INMAN, IM ;
ABREU, SA ;
ZABALETA, IA ;
SACKNER, MA .
PEDIATRIC PULMONOLOGY, 1995, 19 (05) :307-311
[2]  
[Anonymous], 1995, FUZZY SETS FUZZY LOG
[3]  
Bosque Elena, 1993, Pediatric Research, V33, p204A
[4]  
BUCHER HU, 1989, PEDIATRICS, V84, P226
[5]   Comparison of nurse and computer charting of physiological variables in an intensive care unit [J].
Cunningham, S ;
Deere, S ;
Elton, RA ;
McIntosh, N .
INTERNATIONAL JOURNAL OF CLINICAL MONITORING AND COMPUTING, 1996, 13 (04) :235-241
[6]   PULSE OXIMETRY IN PEDIATRIC INTENSIVE-CARE - COMPARISON WITH MEASURED SATURATIONS AND TRANS-CUTANEOUS OXYGEN-TENSION [J].
FANCONI, S ;
DOHERTY, P ;
EDMONDS, JF ;
BARKER, GA ;
BOHN, DJ .
JOURNAL OF PEDIATRICS, 1985, 107 (03) :362-366
[7]   Sleep states and neonatal pulse oximetry [J].
Fletcher, J ;
Page, M ;
Jeffery, HE .
SLEEP, 1998, 21 (03) :305-310
[8]   Comparison of two different pulse oximeters in monitoring preterm infants [J].
Grieve, SH ;
McIntosh, N ;
Laing, IA .
CRITICAL CARE MEDICINE, 1997, 25 (12) :2051-2054
[9]  
Hajek P., 1998, TR LOG STUD LOG LIB, V4
[10]  
HAY WW, 1989, PEDIATRICS, V83, P717