Rotator cuff repair: An ex vivo analysis of suture anchor repair techniques on initial load to failure

被引:69
作者
Cummins, CA
Appleyard, RC
Strickland, S
Haen, PS
Chen, SY
Murrell, GAC
机构
[1] Lake Cook Orthoped Accociates, Barrington, IL 60010 USA
[2] Univ New S Wales, Orthopaed Res Inst, Sydney, NSW, Australia
[3] Hosp Special Surg, New York, NY 10021 USA
关键词
ovine; infraspinatus; rotator cuff; suture anchor; load to failure;
D O I
10.1016/j.arthro.2005.06.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To determine the best combination of anchors and suture techniques for repairing torn rotator cuff tendons. Type of Study: Ex vivo biomechanical investigation. Methods: Sixty fresh-frozen sheep infraspinatus tendons were repaired using 6 different repair techniques: transosseous sutures with 2 sutures and mattress stitches; 2 suture anchors with I suture per anchor using either simple stitches, mattress stitches, or modified Kessler stitches; 2 suture anchors with 2 sutures per anchor using simple stitches; or 5 suture anchors with I suture per anchor and a mattress stitch pattern. Results: No difference was identified between transosseous sutures (mean +/- SD, 147 +/- 68 N) and suture anchors (140 +/- 36 N) when 2 mattress stitches were used. The weakest construct with suture anchors was when the tendon was grasped with 2 suture anchors with I suture per anchor and a simple stitch pattern (72 +/- 25 N). Repair strength increased 2-fold with 2 suture anchors single loaded and a mattress stitch configuration (140 +/- 36 N; P =.026), 3-fold with 2 suture anchors single loaded and a modified Kessler stitch pattern (204 +/- 32 N; P < .001), and 3-fold with 2 suture anchors double loaded and a simple stitch suture pattern (212 +/- 39 N; P < .001). The highest tensile load was observed with 5 suture anchors in a double-row configuration, single loaded, that grasped the tendon with mattress stitches (336 59 N; P < .001). Conclusions: This study shows that in an ovine model, initial rotator cuff repair strength can be enhanced by increasing the number of suture anchors used in the repair and by using anchors that are double loaded with suture and suture configurations that pass more frequently through the tendon. Clinical Relevance: The clinical relevance of this ex vivo investigation is that the initial load to failure of a rotator cuff repair may be increased by increasing the number of suture anchors, the number of sutures per anchor, or using suture patterns that grab more adjacent tendon fibers.
引用
收藏
页码:1236 / 1241
页数:6
相关论文
共 13 条
[1]
Cyclic loading of anchor-based rotator cuff repairs: Confirmation of the tension overload phenomenon and comparison of suture anchor fixation with transosseous fixation [J].
Burkhart, SS ;
Pagan, JLD ;
Wirth, MA ;
Athanasiou, KA .
ARTHROSCOPY, 1997, 13 (06) :720-724
[2]
Arthroscopic rotator cuff repair: Analysis of results by tear size and by repair technique - Margin convergence versus direct tendon-to-bone repair [J].
Burkhart, SS ;
Danaceau, SM ;
Pearce, CE .
ARTHROSCOPY, 2001, 17 (09) :905-912
[3]
Strength of fixation with transosseous sutures in rotator cuff repair [J].
Caldwell, GL ;
Warner, JJP ;
Miller, MD ;
Boardman, D ;
Towers, J ;
Debski, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (07) :1064-1068
[4]
Mode of failure for rotator cuff repair with suture anchors identified at revision surgery [J].
Cummins, CA ;
Murrell, GAC .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (02) :128-133
[5]
Rotator cuff repair with bioabsorbable screws: An in vivo and ex vivo investigation [J].
Cummins, CA ;
Strickland, S ;
Appleyard, RC ;
Szomor, ZL ;
Marshall, J ;
Murrell, GAC .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (03) :239-248
[6]
Arthroscopic repair of full-thickness tears of the rotator cuff [J].
Gartsman, GM ;
Khan, M ;
Hammerman, SM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (06) :832-840
[7]
Experimental rotator cuff repair - A preliminary study [J].
Gerber, C ;
Schneeberger, AG ;
Perren, SM ;
Nyffeler, RW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09) :1281-1290
[8]
MECHANICAL STRENGTH OF REPAIRS OF THE ROTATOR CUFF [J].
GERBER, C ;
SCHNEEBERGER, AG ;
BECK, M ;
SCHLEGEL, U .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (03) :371-380
[9]
REPAIRS OF THE ROTATOR CUFF - CORRELATION OF FUNCTIONAL RESULTS WITH INTEGRITY OF THE CUFF [J].
HARRYMAN, DT ;
MACK, LA ;
WANG, KY ;
JACKINS, SE ;
RICHARDSON, ML ;
MATSEN, FA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (07) :982-989
[10]
Supplementation of rotator cuff repair with a bioresorbable scaffold [J].
Koh, JL ;
Szomor, Z ;
Murrell, GAC ;
Warren, RF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2002, 30 (03) :410-413