摘要
Knowledge of B?1+ distribution is crucial for many applications, such as quantitative MRI. A novel method has been developed to improve the accuracy of the conventionally applied double-angle method for B?1+ mapping. It solves the remaining issues raised by the use of selective pulses for slice selection to accelerate the acquisition process. A general approach for reconstructing B?1+ maps is presented first. It takes B?1+-induced slice profile distortions over off-resonance frequencies into account. It is then shown how the ratio between the prescribed flip angles can be adjusted to reach a compromise between the level of noise propagated onto B?1+ maps and the width of the range in which the field can be mapped. Lastly, several solutions are proposed for reducing the B?1+-dependent pollution of regions distal to the image slice which participates significantly in the inaccuracy of B?1+ mapping. These methods were experimentally tested by comparison with gold standard B?1+ maps obtained on a phantom using a non-selective and thus much slower technique. As they are independent and lead to significant improvements, these solutions can be combined to achieve high precision and fast B?1+ mapping using spin-echo DAM. Magn Reson Med, 2012. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:1472 / 1480
页数:9
相关论文
共 34 条
[1]   RADIOFREQUENCY MAP OF AN NMR COIL BY IMAGING [J].
AKOKA, S ;
FRANCONI, F ;
SEGUIN, F ;
LEPAPE, A .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :437-441
[2]  
[Anonymous], 1992, DATA REDUCTION ERROR
[3]  
BENDALL MR, 1983, J MAGN RESON, V53, P365, DOI 10.1016/0022-2364(83)90211-1
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   RF MAGNETIC-FIELD PENETRATION, PHASE-SHIFT AND POWER DISSIPATION IN BIOLOGICAL TISSUE - IMPLICATIONS FOR NMR IMAGING [J].
BOTTOMLEY, PA ;
ANDREW, ER .
PHYSICS IN MEDICINE AND BIOLOGY, 1978, 23 (04) :630-643
[6]   Rapid high-resolution T1 mapping by variable flip angles:: Accurate and precise measurements in the presence of radiofrequency field inhomogeneity [J].
Cheng, HLM ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (03) :566-574
[7]   Saturated double-angle method for rapid B1 plus mapping [J].
Cunningham, Charles H. ;
Pauly, John M. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) :1326-1333
[8]   High-resolution T1 mapping of the brain at 3T with driven equilibrium single pulse observation of T1 with high-speed incorporation of RF field inhomogeneities (DESPOT1-HIFI) [J].
Deoni, Sean C. L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) :1106-1111
[9]  
Ernst RR, 1987, PRINCIPLES NUCLEAR M, P118
[10]   COMPARISON OF LINEAR AND CIRCULAR-POLARIZATION FOR MAGNETIC-RESONANCE IMAGING [J].
GLOVER, GH ;
HAYES, CE ;
PELC, NJ ;
EDELSTEIN, WA ;
MUELLER, OM ;
HART, HR ;
HARDY, CJ ;
ODONNELL, M ;
BARBER, WD .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (02) :255-270