Strip detector design for ATLAS and HERA-B using two-dimensional device simulation

被引:116
作者
Richter, RH [1 ]
Andricek, L [1 ]
Gebhart, T [1 ]
Hauff, D [1 ]
Kemmer, J [1 ]
Lutz, G [1 ]
Weiss, R [1 ]
Rolf, A [1 ]
机构
[1] UNIV DORTMUND,DEPT PHYS,D-44227 DORTMUND,GERMANY
关键词
D O I
10.1016/0168-9002(96)00257-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Irradiation scenarios were simulated in order to evaluate different technology and design options for silicon strip detectors exposed to a high luminosity environment. Two-dimensional. process and device simulations were performed to get an insight into the device behaviour. The boundary condition of the free oxide regions between the strips was evaluated thoroughly to obtain correct field distributions. Using these results the formation of electron accumulation layers on the surface of the p-side and the depletion voltage dependence on the strip geometry can be explained. We investigated the ''blocking implant'' and the ''spray implant'' techniques as promising candidates for the n-side isolation of irradiated detectors. The main drawback of the ''blocking implanted'' devices is the increase of the electric field with increasing oxide charges. This implies the danger of impact ionization in irradiated devices. A ''spray implanted'' isolation layer leads to the highest electric field in the non-irradiated state which has the advantage of a better testability. Small gaps between strips as used in charge division readout reduce electric fields and leakage currents.
引用
收藏
页码:412 / 421
页数:10
相关论文
共 24 条
[11]  
LUTZ G, 1987, 175 MPIPAE
[12]  
LUTZ G, 1988, VERTEX DETECTORS, P195
[13]   CHARACTERIZATION PROCEDURES FOR DOUBLE-SIDED SILICON MICROSTRIP DETECTORS [J].
BRUNER, NL ;
FRAUTSCHI, MA ;
HOEFERKAMP, MR ;
SEIDEL, SC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 362 (2-3) :315-337
[14]  
MCGARRITY JM, 1989, SEMICONDUCTOR SILICO, P221
[15]  
NICOLLIAN EH, 1982, MOS PHYSICS TECHNOLO
[16]   MICRODISCHARGES OF AC-COUPLED SILICON STRIP SENSORS [J].
OHSUGI, T ;
IWATA, Y ;
OHYAMA, H ;
OHMOTO, T ;
OKADA, M ;
YOSHIKAWA, M ;
TAMURA, N ;
HATAKENAKA, T ;
UNNO, Y ;
KOHRIKI, T ;
UJIIE, N ;
MIYATA, H ;
ASO, T ;
TAKASHIMA, R ;
MURAKAMI, A ;
KOBAYASHI, S ;
YAMAMOTO, K ;
YAMAMURA, K ;
MURAMATSU, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01) :22-26
[17]   EVALUATION OF DOUBLE-SIDED, AC-COUPLED, DOUBLE METAL-SILICON STRIP DETECTORS FOR H1 AT HERA [J].
PITZL, D ;
EICHLER, R ;
ERDMANN, W ;
GABATHULER, K ;
HORISBERGER, R ;
WAGENER, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3) :454-460
[18]  
ROLF A, 1996, 7 EUR S SEM DET SCHL, V377, P284
[19]  
SEDLMEIR J, 1985, THESIS TU MUNCHEN
[20]  
STRECKER N, 1993, DIOS USERS GUIDE