Simultaneous quantification of four vitamin D metabolites in human serum using high performance liquid chromatography tandem mass spectrometry for vitamin D profiling

被引:61
作者
Baecher, Silvia [1 ]
Leinenbach, Andreas [1 ]
Wright, Jo Anne [1 ]
Pongratz, Stephan [1 ]
Kobold, Uwe [1 ]
Thiele, Roland [1 ]
机构
[1] Roche Diagnost GmbH, D-82377 Penzberg, Germany
关键词
25-Hydroxyvitamin D-3; 25-Hydroxyvitamin D-2; 3-Epi-25-hydroxyvitamin D-3; 24R; 25-Dihydroxyvitamin D-3; HPLC-MS/MS; Vitamin D profiling; 25-HYDROXYVITAMIN D-3; 24,25-DIHYDROXYVITAMIN D-3; DERIVATIZATION; INFANTS; ACCOUNT; EPIMERS; MS/MS;
D O I
10.1016/j.clinbiochem.2012.06.030
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: For quantification of 25-hydroxyvitamin D-3 (25OH-D-3), 25-hydroxyvitamin D-2 (25OH-D-2). 3-epi-25-hydroxyvitamin D-3 (3-epi-25OH-D-3) and 24R,25-dihydroxyvitamin D-3 (24R,25(OH)(2)-D-3) in human serum a high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method was developed and validated. Design and methods: After protein precipitation further purification is achieved with on-line sample preparation using a reversed phase (RP) C-4 column. Chromatographic separation is realized by a RP-column with core shell material and pentafluorophenyl (PFP) selectivity. Atmospheric pressure chemical ionization in the positive ion mode with multi-reaction monitoring is used for analyte detection. Results: Baseline separation of the analytes is achieved below 10 min. The method is linear over the range 4.0-2653 nmol/L for 25OH-D-3, 3.9-183.6 nmol/L for 25OH-D-2, 2.0-133.8 nmol/L for 3-epi-25OH-D-3 and 2.8-129.9 nmol/L for 24R,25(OH)(2)-D-3 (r(2)>0.998). The limit of quantification is 4.0 nmol/L for 25OH-D-3, 3.9 nmol/L for 25OH-D-2, 2.0 nmol/L for 3-epi-25OH-D-3 and 2.8 nmol/L for 24R,25(OH)(2)-D-3. The CVs for the intra-day and inter-day precision are <5% and <4%, respectively. Metabolite levels for a set of 50 human serum samples have been determined and resulted in the detection of considerable amounts of 3-epi-25OH-D-3 and 24R,25(OH)(2)-D-3. Conclusions: This highly specific HPLC-MS/MS method is suitable for vitamin D profiling. There is a correlation between 25OH-D-3 and 24R,25(OH)(2)-D-3. Serum concentration of 24R,25(OH)(2)-D-3 increases disproportionally with increasing concentration of 25OH-D-3. (C) 2012 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1491 / 1496
页数:6
相关论文
共 27 条
[1]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[2]  
[Anonymous], 2009, CERT AN STAND REF MA
[3]   Metabolic profiling of major vitamin D metabolites using Diels-Alder derivatization and ultra-performance liquid chromatography-tandem mass spectrometry [J].
Aronov, Pavel A. ;
Hall, Laura M. ;
Dettmer, Katja ;
Stephensen, Charles B. ;
Hammock, Bruce D. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1917-1930
[4]   Determination of serum vitamins 25-OH-D2 and 25-OH-D3 with liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization or electrospray source and core-shell or sub-2 μm particle columns: A comparative study [J].
Bogusz, Maciej J. ;
Al Enazi, Eid ;
Tahtamoni, Monther ;
Jawaad, Jamil Abdel ;
Al Tufail, Mohammed .
CLINICAL BIOCHEMISTRY, 2011, 44 (16) :1329-1337
[5]   Quantitative determination of vitamin D metabolites in plasma using UHPLC-MS/MS [J].
Ding, Shujing ;
Schoenmakers, Inez ;
Jones, Kerry ;
Koulman, Albert ;
Prentice, Ann ;
Volmer, Dietrich A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) :779-789
[6]   Ultrasensitive Quantification of Serum Vitamin D Metabolites Using Selective Solid-Phase Extraction Coupled to Microflow Liquid Chromatography and Isotope-Dilution Mass Spectrometry [J].
Duan, Xiaotao ;
Weinstock-Guttman, Bianca ;
Wang, Hao ;
Bang, Eunjin ;
Li, Jun ;
Ramanathan, Murali ;
Qu, Jun .
ANALYTICAL CHEMISTRY, 2010, 82 (06) :2488-2497
[7]   Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analogues [J].
El-Khoury, Joe M. ;
Reineks, Edmunds Z. ;
Wang, Sihe .
CLINICAL BIOCHEMISTRY, 2011, 44 (01) :66-76
[8]   Determination of 24,25-dihydroxyvitamin D3 in human plasma using liquid chromatography-mass spectrometry after derivatization with a Cookson-type reagent [J].
Higashi, T ;
Awada, D ;
Shimada, K .
BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (02) :133-140
[9]   A specific LC/ESI-MS/MS method for determination of 25-hydroxyvitamin D3 in neonatal dried blood spots containing a potential interfering metabolite, 3-epi-25-hydroxyvitamin D3 [J].
Higashi, Tatsuya ;
Suzuki, Masahiro ;
Hanai, Junji ;
Inagaki, Shinsuke ;
Min, Jun Zhe ;
Shimada, Kazutake ;
Toyo'oka, Toshimasa .
JOURNAL OF SEPARATION SCIENCE, 2011, 34 (07) :725-732
[10]   Advances in determination of vitamin D related compounds in biological samples using liquid chromatography-mass spectrometry: A review [J].
Higashi, Tatsuya ;
Shimada, Kazutake ;
Toyo'oka, Toshimasa .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (20) :1654-1661