Determination of isoelectric point and investigation of immunoreaction in peanut allergenic proteins-rabbit IgG antibody system by whole-column imaged capillary isoelectric focusing

被引:18
作者
Wu, XZ
Huang, TM
Mullett, WM
Yeung, JM
Pawliszyn, J
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Natl Food Processors Assoc, Washington, DC 20005 USA
关键词
whole column imaging; capillary isoelectric focusing; peanut allergenic protein; rabbit IgG antibody; immunoreaction;
D O I
10.1002/mcs.10013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The recently developed whole-column imaged capillary isoelectric focusing focusing is an advanced technique for the pI determination of proteins. In this study, we initially applied this technique to determine the pI of peanut allergens and its antibody, rabbit IgG. Two main proteins, Ara h I and Ara h II, were found in the peanut allergen solution. Their pI values were determined to be about 4.5-4.7 and 5.1-5.6, respectively. The value of pI for the antibody rabbit IgG was 6.1-6.5. Second, the immunoreaction selectivity of the two main peanut allergenic proteins with antibody rabbit IgG was studied. The CIEF results show that the peanut allergen Ara h II has a larger affinity for binding to the antibody rabbit IgG than Ara h I. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:322 / 326
页数:5
相关论文
共 21 条
[11]  
RIGHETTI PG, 1981, J CHROMATOGR, V220, P115, DOI 10.1016/S0021-9673(00)88456-3
[12]  
TAMARA KJ, 1999, INT ARCH ALLERGY IMM, V119, P265
[13]   DUAL DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING WITH REFRACTIVE-INDEX GRADIENT AND ABSORPTION IMAGING DETECTORS [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (06) :867-873
[14]   UNIVERSAL DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING WITHOUT MOBILIZATION USING A CONCENTRATION GRADIENT IMAGING-SYSTEM [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :224-227
[15]   ABSORPTION-SPECTRA AND MULTICAPILLARY IMAGING DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING USING A CHARGE-COUPLED-DEVICE CAMERA [J].
WU, JQ ;
PAWLISZYN, J .
ANALYST, 1995, 120 (05) :1567-1571
[16]   Capillary isoelectric focusing with whole column detection and a membrane sample preparation system [J].
Wu, JQ ;
Tragas, C ;
Watson, A ;
Pawliszyn, J .
ANALYTICA CHIMICA ACTA, 1999, 383 (1-2) :67-78
[17]   Optimizing separation conditions for proteins and peptides using imaged capillary isoelectric focusing [J].
Wu, JQ ;
Li, SC ;
Watson, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 817 (1-2) :163-171
[18]   DIODE LASER-BASED CONCENTRATION GRADIENT IMAGING DETECTOR FOR CAPILLARY ISOELECTRIC-FOCUSING [J].
WU, JQ ;
PAWLISZYN, J .
ANALYTICA CHIMICA ACTA, 1995, 299 (03) :337-342
[19]  
WU JQ, 1994, AM LAB, V26, P48
[20]   FLUORESCENCE IMAGING DETECTION FOR CAPILLARY ISOELECTRIC-FOCUSING [J].
WU, XZ ;
WU, JQ ;
PAWLISZYN, J .
ELECTROPHORESIS, 1995, 16 (08) :1474-1478