Capillary isoelectric focusing with whole column detection and a membrane sample preparation system

被引:37
作者
Wu, JQ
Tragas, C
Watson, A
Pawliszyn, J [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Convergent Biosci Ltd, Toronto, ON M8Z 2L8, Canada
关键词
capillary isoelectric focusing; whole column detector; imaging detector; on-line desalting device; protein analysis;
D O I
10.1016/S0003-2670(98)00489-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Progress of the research on capillary isoelectric focusing (clEF)-whole column detection is reviewed. Three kinds of whole column detectors have been developed for cIEF: universal refractive index gradient imaging detector, laser-induced fluorescence (LIF) imaging detector, and optical absorption detector. Principle, applicability and detection limit of these detectors are discussed. A capillary column cartridge specially designed for cIEF with whole column detection is introduced. The column cartridge uses microdialysis hollow fiber membranes to isolate the sample solution from the electrolytes. Sample can be directly injected into the column without disturbing the electrolytes using a syringe pump or a liquid chromatography autosampler. The cartridge incorporates an on-line desalting, carrier ampholytes mixing device which also uses a microdialysis hollow fiber membrane. The on-line device adapts cIEF to a variety of analytical matrices. Examples of application of different whole column detectors to cIEF are shown in the review. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:67 / 78
页数:12
相关论文
共 20 条
[1]   SPATIAL-SCANNING LASER FLUORESCENCE DETECTION FOR CAPILLARY ELECTROPHORESIS [J].
BEALE, SC ;
SUDMEIER, SJ .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3367-3371
[2]  
HEMPE JM, 1994, CLIN CHEM, V40, P2288
[3]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[4]   MOLECULAR-WEIGHT SENSING OF POLYETHYLENE GLYCOLS BY FLOW-INJECTION ANALYSIS AND REFRACTIVE-INDEX GRADIENT DETECTION [J].
MURUGAIAH, V ;
SYNOVEC, RE .
ANALYTICA CHIMICA ACTA, 1991, 246 (01) :241-249
[5]  
NILSSON S, 1995, J CAPILLARY ELECTROP, V2, P46
[6]   Capillary isoelectric focusing [J].
Rodriguez-Diaz, R ;
Wehr, T ;
Zhu, MD .
ELECTROPHORESIS, 1997, 18 (12-13) :2134-2144
[7]   QUANTITATIVE ESTIMATION OF ABNORMAL MICROHETEROGENEITY OF SERUM TRANSFERRIN IN ALCOHOLICS [J].
STIBLER, H ;
SYDOW, O ;
BORG, S .
PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1980, 13 :47-51
[8]   N-GLYCOSYLATION OF SERUM-PROTEINS IN DISEASE AND ITS INVESTIGATION USING LECTINS [J].
TURNER, GA .
CLINICA CHIMICA ACTA, 1992, 208 (03) :149-171
[9]   ONLINE DIALYSIS AS A SAMPLE-PREPARATION TECHNIQUE FOR COLUMN LIQUID-CHROMATOGRAPHY [J].
VANDEMERBEL, NC ;
BRINKMAN, UAT .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (06) :249-256
[10]   PEPTIDE-MAPPING OF BOVINE AND CHICKEN CYTOCHROME-C BY CAPILLARY ISOELECTRIC-FOCUSING WITH UNIVERSAL CONCENTRATION GRADIENT IMAGING [J].
VONGUYEN, L ;
WU, JQ ;
PAWLISZYN, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1994, 657 (02) :333-338