A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology

被引:337
作者
Erlandsson, Kjell [1 ]
Buvat, Irene [2 ]
Pretorius, P. Hendrik [3 ]
Thomas, Benjamin A. [1 ]
Hutton, Brian F. [1 ]
机构
[1] UCL, Inst Nucl Med, London, England
[2] CNRS, UMR 8165, IMNC, F-91406 Orsay, France
[3] Univ Massachusetts, Sch Med, Dept Radiol, Div Nucl Med, Worcester, MA USA
基金
英国工程与自然科学研究理事会;
关键词
STANDARDIZED UPTAKE VALUE; MYOCARDIAL BLOOD-FLOW; MESOLIMBIC DOPAMINE TRANSMISSION; OF-INTEREST EVALUATION; POSITRON-EMISSION; IMAGE-RECONSTRUCTION; TUMOR RESPONSE; MONTE-CARLO; FDG PET; EXPECTATION MAXIMIZATION;
D O I
10.1088/0031-9155/57/21/R119
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate quantification in PET and SPECT requires correction for a number of physical factors, such as photon attenuation, Compton scattering and random coincidences (in PET). Another factor affecting quantification is the limited spatial resolution. While considerable effort has gone into development of routine correction techniques for the former factors, less attention has been paid to the latter. Spatial resolution-related effects, referred to as 'partial volume effects' (PVEs), depend not only on the characteristics of the imaging system but also on the object and activity distribution. Spatial and/or temporal variations in PVE can often be confounding factors. Partial volume correction (PVC) could in theory be achieved by some kind of inverse filtering technique, reversing the effect of the system PSF. However, these methods are limited, and usually lead to noise-amplification or image artefacts. Some form of regularization is therefore needed, and this can be achieved using information from co-registered anatomical images, such as CT or MRI. The purpose of this paper is to enhance understanding of PVEs and to review possible approaches for PVC. We also present a review of clinical applications of PVC within the fields of neurology, cardiology and oncology, including specific examples.
引用
收藏
页码:R119 / R159
页数:41
相关论文
共 167 条
[21]   Regularized image reconstruction with an anatomically adaptive prior for positron emission tomography [J].
Chan, Chung ;
Fulton, Roger ;
Feng, David Dagan ;
Meikle, Steven .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24) :7379-7400
[22]   Effects of Image Characteristics on Performance of Tumor Delineation Methods: A Test-Retest Assessment [J].
Cheebsumon, Patsuree ;
van Velden, Floris H. P. ;
Yaqub, Maqsood ;
Frings, Virginie ;
de Langen, Adrianus J. ;
Hoekstra, Otto S. ;
Lammertsma, Adriaan A. ;
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (10) :1550-1558
[23]   SENSOR FUSION IN IMAGE-RECONSTRUCTION [J].
CHEN, CT ;
OUYANG, XL ;
WONG, WH ;
HU, XP ;
JOHNSON, VE ;
ORDONEZ, C ;
METZ, CE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :687-692
[24]   Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels [J].
Comtat, C ;
Kinahan, PE ;
Fessler, JA ;
Beyer, T ;
Townsend, DW ;
Defrise, M ;
Michel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) :1-20
[25]   Age-Related Metabolic Profiles in Cognitively Healthy Elders: Results from a Voxel-Based [18F]Fluorodeoxyglucose-Positron-Emission Tomography Study with Partial Volume Effects Correction [J].
Curiati, P. K. ;
Tamashiro-Duran, J. H. ;
Duran, F. L. S. ;
Buchpiguel, C. A. ;
Squarzoni, P. ;
Romano, D. C. ;
Vallada, H. ;
Menezes, P. R. ;
Scazufca, M. ;
Busatto, G. F. ;
Alves, T. C. T. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (03) :560-565
[26]  
Da Silva AJ, 2001, J NUCL MED, V42, P772
[27]  
Da Silva AJ, 1999, IEEE T NUCL SCI, V46, P659, DOI 10.1109/23.775595
[28]   Preliminary study of the detectability of coronary plaque with PET [J].
Delso, G. ;
Martinez-Moeller, A. ;
Bundschuh, R. A. ;
Nekolla, S. G. ;
Ziegler, S. I. ;
Schwaiger, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (07) :2145-2160
[29]   Partial volume effect compensation for quantitative brain SPECT imaging [J].
Du, Y ;
Tsui, BMW ;
Frey, EC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (08) :969-976
[30]   Partial Volume Correction in SPECT Using Anatomical Information and Iterative FBP [J].
Erlandsson K. ;
Hutton B.F. .
Tsinghua Science and Technology, 2010, 15 (01) :50-55