Ankle: Isotropic MR Imaging with 3D-FSE-Cube-Initial Experience in Healthy Volunteers

被引:119
作者
Stevens, Kathryn J. [1 ]
Busse, Reed F. [2 ]
Han, Eric [2 ]
Brau, Anja C. S. [2 ]
Beatty, Philip J. [2 ]
Beaulieu, Christopher F. [1 ]
Gold, Garry E. [1 ]
机构
[1] Stanford Univ, Med Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] GE Healthcare Global Appl Sci Lab, Menlo Pk, CA USA
基金
美国国家卫生研究院;
关键词
D O I
10.1148/radiol.2493080227
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
The purpose of this prospective study was to compare a new isotropic three-dimensional (3D) fast spin-echo (FSE) pulse sequence with parallel imaging and extended echo train acquisition (3D-FSE-Cube) with a conventional two-dimensional (2D) FSE sequence for magnetic resonance (MR) imaging of the ankle. After institutional review board approval and informed consent were obtained and in accordance with HIPAA privacy guidelines, MR imaging was performed in the ankles of 10 healthy volunteers (four men, six women; age range, 25-41 years). Imaging with the 3D-FSE-Cube sequence was performed at 3.0 T by using both one-dimensional- and 2D-accelerated autocalibrated parallel imaging to decrease imaging time. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) with 3D-FSE-Cube were compared with those of the standard 2D FSE sequence. Cartilage, muscle, and fluid SNRs were significantly higher with the 3D-FSE-Cube sequence (P < .01 for all). Fluid-cartilage CNR was similar for both techniques. The two sequences were also compared for overall image quality, blurring, and artifacts. No significant difference for overall image quality and artifacts was demonstrated between the 2D FSE and 3D-FSE-Cube sequences, although the section thickness in 3D-FSE-Cube imaging was much thinner (0.6 mm). However, blurring was significantly greater on the 3D-FSE-Cube images (P < .04). The 3D-FSE-Cube sequence with isotropic resolution is a promising new MR imaging sequence for viewing complex joint anatomy. (c) RSNA, 2008
引用
收藏
页码:1026 / 1033
页数:8
相关论文
共 34 条
[1]
Imaging articular cartilage defects in the ankle joint with 3D fat-suppressed echo planar imaging: Comparison with conventional 3D fat-suppressed gradient echo imaging [J].
Ba-Ssalamah, A ;
Schibany, N ;
Puig, S ;
Herneth, AM ;
Noebauer-Huhmann, IM ;
Trattnig, S .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (02) :209-216
[2]
Beatty P., 2007, P 15 ANN M ISMRM BER, V15, P1749
[3]
Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods [J].
Brau, Anja C. S. ;
Beatty, Philip J. ;
Skare, Stefan ;
Bammer, Roland .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) :382-395
[4]
Fast spin echo sequences with very long echo trains:: Design of variable refocusing flip angle schedules and generation of clinical T2 contrast [J].
Busse, RF ;
Hariharan, H ;
Vu, A ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1030-1037
[5]
BUSSE RF, 2007, P 15 M INT SOC MAGN, P345
[6]
Cheung Y, 2001, Magn Reson Imaging Clin N Am, V9, P507
[7]
Cartilage thickness in cadaveric ankles: Measurement with double-contrast multi-detector row CT arthrography versus MR imaging [J].
El-Khoury, GY ;
Alliman, KJ ;
Lundberg, HJ ;
Rudert, MJ ;
Brown, TD ;
Saltzman, CL .
RADIOLOGY, 2004, 233 (03) :768-773
[8]
A systematic review on ankle injury and ankle sprain in sports [J].
Fong, Daniel Tik-Pui ;
Hong, Youlian ;
Chan, Lap-Ki ;
Yung, Patrick Shu-Hang ;
Chan, Kai-Ming .
SPORTS MEDICINE, 2007, 37 (01) :73-94
[9]
A comparison of MRI and clinical examination of acute lateral ankle sprains [J].
Frey, C ;
Bell, J ;
Teresi, L ;
Kerr, R ;
Feder, K .
FOOT & ANKLE INTERNATIONAL, 1996, 17 (09) :533-537
[10]
Musculoskeletal MRI at 3.0T: Relaxation times and image contrast [J].
Gold, GE ;
Han, E ;
Stainsby, J ;
Wright, G ;
Brittain, J ;
Beaulieu, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (02) :343-351