Bioelectrochemical characteristics of cholesterol oxidase immobilized in a polyaniline film

被引:105
作者
Wang, HY [1 ]
Mu, SL [1 ]
机构
[1] Yangzhou Univ, Teachers Coll, Dept Chem, Yangzhou 225002, Peoples R China
关键词
cholesterol oxidase; polyaniline film; immobilization; bioelectrochemical response to cholesterol; XPS spectra;
D O I
10.1016/S0925-4005(99)00025-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cholesterol oxidase has been immobilized in polyaniline film by the electrochemical doping method. The measurements of the response current are carried out in the solutions containing cholesterol and Triton X-100 of 5% and 1%, respectively. The latter is necessary for solubilizing cholesterol. The response current of the polyaniline cholesterol oxidase electrode increases with increasing potential from 0.35 to 0.60 V (vs. SCE). A maximum response current occurs at 0.60 V, which is independent of the concentration of Triton X-100. The response current of the enzyme electrode at TritbnX-100 of 1% is about twice as high as that at Triton X-100 of 5%; The optimum pH and the optimum temperature of the immobilized cholesterol oxidase are 7.26 and 35 degrees C, respectively. The activation energy of the enzyme-catalyzed reaction is 71.1 kJ mol(-1) at Triton X-100 of 5% and 67.4 kJ mol(-1) at Triton X-100 of 1%. The apparent Michaelis-Menten constant K-m' is 2.72 mmol dm(-3) at 0.45 V and 3.26 mmol dm-3 at 0.60 V for Triton X-100 of 5%, and 0.51 mmol dm(-3) at 0.45 V and 0.56 mmol dm(-3) at 0.60 V for Triton X-100 of 1%. The response current of the enzyme electrode increases linearly with increasing concentration of cholesterol in the range 0.05-0.5 mmol dm(-3) at 0.45 V and 0.05 to 0.2 mmol dm(-3) at 0.60 V for Triton X-100 of 5%, and 0.01 to 0.1 mmol dm(-3) at both potentials of 0.45 and 0.60 V for Triton X-100 of 1%. The response current of the enzyme electrode drops to 51% of its initial value after 11 days. During this period, this enzyme electrode is employed to determine the substrate solved in Triton X-100 of 1% at different conditions for 230 times. Thus, the polyaniline cholesterol oxidase electrode can be used to determine cholesterol concentration. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:22 / 30
页数:9
相关论文
共 26 条
[1]   ELECTROCHEMICAL SENSORS - THEORY AND EXPERIMENT [J].
ALBERY, WJ ;
BARTLETT, PN ;
CASS, AEG ;
CRASTON, DH ;
HAGGETT, BGD .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1033-1050
[2]   STRATEGIES FOR THE DEVELOPMENT OF AMPEROMETRIC ENZYME ELECTRODES [J].
BARTLETT, PN ;
WHITAKER, RG .
BIOSENSORS, 1988, 3 (06) :359-379
[3]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[4]   MULTIPURPOSE ELECTRODE WITH DIFFERENT ENZYME-SYSTEMS BOUND TO COLLAGEN FILMS [J].
BERTRAND, C ;
COULET, PR ;
GAUTHERON, DC .
ANALYTICA CHIMICA ACTA, 1981, 126 (MAY) :23-34
[5]   Improvement of the analytical characteristics of an enzyme electrode for free and total cholesterol via laponite clay additives [J].
Besombes, JL ;
Cosnier, S ;
Labbe, P ;
Reverdy, G .
ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) :275-280
[6]   Amperometric determination of cholesterol in serum with use of a renewable surface peroxidase electrode [J].
Charpentier, L ;
ElMurr, N .
ANALYTICA CHIMICA ACTA, 1995, 318 (01) :89-93
[7]   ELECTROCHEMICAL RESPONSE OF AN ENZYME-LOADED POLYANILINE FILM [J].
COOPER, JC ;
HALL, EAH .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (07) :473-485
[8]   ENZYME ENTRAPMENT IN ELECTRICALLY CONDUCTING POLYMERS - IMMOBILIZATION OF GLUCOSE-OXIDASE IN POLYPYRROLE AND ITS APPLICATION IN AMPEROMETRIC GLUCOSE SENSORS [J].
FOULDS, NC ;
LOWE, CR .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1259-1264
[9]  
FRANCK C, 1989, BIOCHIM BIOPHYS ACTA, V999, P233
[10]   FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR [J].
GILMARTIN, MAT ;
HART, JP .
ANALYST, 1994, 119 (11) :2331-2336