Accelerated parallel imaging for functional imaging of the human brain

被引:46
作者
de Zwart, JA
van Gelderen, P
Golay, X
Ikonomidou, VN
Duyn, JH
机构
[1] NINDS, Adv MRI Sect, LFMI, NIH, Bethesda, MD 20892 USA
[2] Natl Inst Neurosci, Dept Neuroradiol, Singapore, Singapore
关键词
parallel imaging; fMRI; rapid imaging; echo-planar imaging; geometrical distortions; SENSE; SMASH;
D O I
10.1002/nbm.1043
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Accelerated parallel imaging (PI) techniques have recently been applied to functional imaging experiments of the human brain in order to improve the performance of commonly used single-shot techniques like echo-planar imaging (EPI). Potential benefits of PI-fMRI include the reduction of geometrical distortions due to off-resonance signals, the reduction of signal-loss in areas with substantial signal inhomogeneity, increases of the spatial and temporal resolution of the fMR1 experiment and reduction of gradient acoustic noise. Although PI generally leads to a substantial decrease in image signal-to-noise ratio (SNR), its effect on the temporal stability of the signal, which ultimately determines fMRI performance, is only partially determined by image SNR. Therefore, the penalty for using PI is generally not as severe as the SNR reduction. The majority of problems related to single-shot techniques become more severe at an increased magnetic field strength, making PI an important tool in achieving the full potential of fMRI at high field. Copyright (C) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:342 / 351
页数:10
相关论文
共 108 条
[71]   ACTIVE ACOUSTIC SCREENING - REDUCTION OF NOISE IN GRADIENT COILS BY LORENTZ FORCE BALANCING [J].
MANSFIELD, P ;
CHAPMAN, BLW ;
BOWTELL, R ;
GLOVER, P ;
COXON, R ;
HARVEY, PR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (02) :276-281
[72]   Acoustic noise concerns in functional magnetic resonance imaging [J].
Moelker, A ;
Pattynama, PMT .
HUMAN BRAIN MAPPING, 2003, 20 (03) :123-141
[73]   Relationship between magnetic field strength and magnetic-resonance-related acoustic noise levels [J].
Moelker, A ;
Wielopolski, PA ;
Pattynama, PMT .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2003, 16 (01) :52-55
[74]  
MORGAN PS, 2004, P 12 ISMRM KYOT, P1030
[75]   Effects of noise from functional magnetic resonance imaging on auditory event-related potentials in working memory task [J].
Novitski, N ;
Anourova, I ;
Martinkauppi, S ;
Aronen, HJ ;
Näätänen, R ;
Carlson, S .
NEUROIMAGE, 2003, 20 (02) :1320-1328
[76]   Quiet imaging with interleaved spiral read-out [J].
Oesterle, C ;
Hennel, F ;
Hennig, J .
MAGNETIC RESONANCE IMAGING, 2001, 19 (10) :1333-1337
[77]   FUNCTIONAL BRAIN MAPPING BY BLOOD OXYGENATION LEVEL-DEPENDENT CONTRAST MAGNETIC-RESONANCE-IMAGING - A COMPARISON OF SIGNAL CHARACTERISTICS WITH A BIOPHYSICAL MODEL [J].
OGAWA, S ;
MENON, RS ;
TANK, DW ;
KIM, SG ;
MERKLE, H ;
ELLERMANN, JM ;
UGURBIL, K .
BIOPHYSICAL JOURNAL, 1993, 64 (03) :803-812
[78]   Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations [J].
Ohliger, MA ;
Grant, AK ;
Sodickson, DK .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) :1018-1030
[79]   Perfusion-based high-resolution functional Imaging in the human brain at 7 tesla [J].
Pfeuffer, J ;
Adriany, G ;
Shmuel, A ;
Yacoub, E ;
Van de Moortele, PF ;
Hu, X ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) :903-911
[80]   Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI) [J].
Preibisch, C ;
Pilatus, U ;
Bunke, R ;
Hoogenraad, F ;
Zanella, F ;
Lanfermann, H .
NEUROIMAGE, 2003, 19 (02) :412-421