Correlation between image noise and body weight in coronary CTA with 16-row MDCT

被引:45
作者
Yoshimura, N [1 ]
Sabir, A [1 ]
Kubo, T [1 ]
Lin, PJP [1 ]
Clouse, ME [1 ]
Hatabu, H [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
关键词
coronary CT; radiation dose; body weight; image noise;
D O I
10.1016/j.acra.2005.11.036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To evaluate the correlation between image noise and body weight (BW) or body mass index (BMI) in coronary computed tomography angiography (CTA) as a potential parameter for reducing radiation dose in coronary CTA. Materials and Methods. Thirty-six patients who underwent electrocardiogram-gated cardiac CT were analyzed in this study. The patients included 26 men and 10 women with a mean age of 60 years (range 43-79 years). All patients were imaged on a 16-row multidetector CT scanner. Mean value of BW and BMI was 83.5 kg and 28.1, respectively. Image noise was defined as standard deviation (SD) of the attenuation values measured by using 1 cm(2) circular region of interest in the ascending aorta at the level of the right main pulmonary artery. The SD values were plotted against BW and BMI. The correlations were examined using a linear regression method. A P value of less than.05 was considered significant. Results. The r value of linear regression between noise and BW was 0.90 (P < .001). The r value of linear regression between noise and BMI was 0.74 (P = .015). Conclusions. Excellent correlation was observed between noise and BW in coronary CTA. These data may be used as potential parameters for customized radiation dose modification to reduce radiation dose in coronary CT examinations.
引用
收藏
页码:324 / 328
页数:5
相关论文
共 22 条
[1]   Risk of cancer from diagnostic X-rays:: estimates for the UK and 14 other countries [J].
Berrington de González, A ;
Darby, S .
LANCET, 2004, 363 (9406) :345-351
[2]   Estimated radiation risks potentially associated with full-body CT screening [J].
Brenner, DJ ;
Elliston, CD .
RADIOLOGY, 2004, 232 (03) :735-738
[3]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[4]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97
[5]   Predictive value of 16-slice multidetector spiral computed tomography to detect significant obstructive coronary artery disease in patients at high risk for coronary artery disease - Patient-versus segment-based analysis [J].
Hoffmann, U ;
Moselewski, F ;
Cury, RC ;
Ferencik, M ;
Jang, IK ;
Diaz, LJ ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
CIRCULATION, 2004, 110 (17) :2638-2643
[6]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[7]   Radiation exposure during cardiac CT: Effective doses at multi-detector row CT and electron-beam CT [J].
Hunold, P ;
Vogt, FM ;
Schmermund, A ;
Debatin, JF ;
Kerkhoff, G ;
Budde, T ;
Erbel, R ;
Ewen, K ;
Barkhausen, J .
RADIOLOGY, 2003, 226 (01) :145-152
[8]   Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation [J].
Jakobs, TF ;
Becker, CR ;
Ohnesorge, B ;
Flohr, T ;
Suess, C ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (05) :1081-1086
[9]   SELECTIVE CORONARY ARTERIOGRAPHY .I. A PERCUTANEOUS TRANSFEMORAL TECHNIC [J].
JUDKINS, MP .
RADIOLOGY, 1967, 89 (05) :815-&
[10]   Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart [J].
Jung, B ;
Mahnken, AH ;
Stargardt, A ;
Simon, J ;
Flohr, TG ;
Schaller, S ;
Koos, R ;
Günther, RW ;
Wildberger, JE .
EUROPEAN RADIOLOGY, 2003, 13 (12) :2560-2566