Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart

被引:56
作者
Jung, B
Mahnken, AH
Stargardt, A
Simon, J
Flohr, TG
Schaller, S
Koos, R
Günther, RW
Wildberger, JE
机构
[1] Aachen Univ Hosp, Univ Technol, Dept Diagnost Radiol, D-52074 Aachen, Germany
[2] Siemens Med Solut, Forchheim, Germany
[3] Aachen Univ Hosp, Univ Technol, Med Clin 1, D-52074 Aachen, Germany
关键词
computed tomography; heart CT; dosage reduction;
D O I
10.1007/s00330-003-2111-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A(1)) a standard protocol with constant tube current-time settings was used (4x1-mm collimation, 120 kV, 400 mAs(eff)). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A(2)). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were evaluated by a regression analysis. The image quality was assessed objectively by measuring the CT attenuation in standardised regions of interest and subjectively by three radiologists using a five-point scoring system in a consensus reading. Applying the weight-adapted tube current-time settings the effective radiation dose was reduced by 17.9% for men and 26.3% for women. The standard protocol leads to an overexposure in light patients as seen in the plot of noise vs weight (slope 0.16+/-0.07 HU/kg). By applying the weight-adapted tube current-time settings a weight-independent, constant image noise is achieved (slope 0.04+/-0.1 HU/kg). Diagnostic image quality was preserved in all patients. Individually weight-adapted tube current-time settings allow for a substantial dose reduction when performing retrospectively ECG-gated MSCT angiography for coronary arteries without impairment of diagnostic image quality.
引用
收藏
页码:2560 / 2566
页数:7
相关论文
共 26 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]   Coronary artery calcium measurement: Agreement of multirow detector and electron beam CP [J].
Becker, CR ;
Kleffel, T ;
Crispin, A ;
Knez, A ;
Young, J ;
Schoepf, UJ ;
Haberl, R ;
Reiser, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1295-1298
[3]   Radiation exposure in multi-slice CT of the heart [J].
Cohnen, M ;
Poll, L ;
Püttmann, C ;
Ewen, K ;
Mödder, U .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (04) :295-299
[4]  
*COMM EUR COMM, 1998, 16262 EUR EUR COMM
[5]   Spiral CT of the abdomen: Weight-adjusted dose reduction. [J].
Coppenrath, E ;
Schmid, C ;
Brandl, R ;
Szeimies, U ;
Hahn, K .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (01) :52-56
[6]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[7]   Heart rate adaptive optimization of spatial and temporal resolution for electrocardiogram-gated multislice spiral CT of the heart [J].
Flohr, T ;
Ohnesorge, B .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) :907-923
[8]   Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients [J].
Frush, DP ;
Slack, CC ;
Hollingsworth, CL ;
Bisset, GS ;
Donnelly, LF ;
Hsieh, J ;
Lavin-Wensell, T ;
Mayo, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (05) :1107-1113
[9]   Dose reduction in CT examination of children by an attenuation-based on-line modulation of tube current (CARE Dose) [J].
Greess, H ;
Nömayr, A ;
Wolf, H ;
Baum, U ;
Lell, M ;
Böwing, B ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1571-1576
[10]   Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions [J].
Greess, H ;
Wolf, H ;
Baum, U ;
Lell, M ;
Pirkl, M ;
Kalender, W ;
Bautz, WA .
EUROPEAN RADIOLOGY, 2000, 10 (02) :391-394