A method of image registration for small animal, multi-modality imaging

被引:77
作者
Chow, PL [1 ]
Stout, DB [1 ]
Komisopoulou, E [1 ]
Chatziioannou, AF [1 ]
机构
[1] Univ Calif Los Angeles, Crump Inst Mol Imaging, Los Angeles, CA 90095 USA
关键词
D O I
10.1088/0031-9155/51/2/013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Many research institutions have a full suite of preclinical tomographic scanners to answer biomedical questions in vivo. Routine multi-modality imaging requires robust registration of images generated by various tomographs. We have implemented a hardware registration method for preclinical imaging that is similar to that used in the combined positron emission tomography (PET)/computed tomography (CT) scanners in the clinic. We designed an imaging chamber which can be rigidly and reproducibly mounted on separate microPET and microCT scanners. We have also designed a three-dimensional grid phantom with 1288 lines that is used to generate the spatial transformation matrix from software registration using a 15-parameter perspective model. The imaging chamber works in combination with the registration phantom synergistically to achieve the image registration goal. We verified that the average registration error between two imaging modalities is 0.335 mm using an in vivo mouse bone scan. This paper also estimates the impact of image misalignment on PET quantitation using attenuation corrections generated from misregistered images. Our technique is expected to produce PET quantitation errors of less than 5%. The methods presented are robust and appropriate for routine use in high throughput animal imaging facilities.
引用
收藏
页码:379 / 390
页数:12
相关论文
共 21 条
[11]   3D multimodality medical image registration using morphological tools [J].
Maintz, JBA ;
van den Elsen, PA ;
Viergever, MA .
IMAGE AND VISION COMPUTING, 2001, 19 (1-2) :53-62
[12]  
*PARK HANN CORP DA, 100532001 PARK HANN
[13]  
Ray P, 2003, CANCER RES, V63, P1160
[14]  
Stout D. B., 2003, MOL IMAGING BIOL, V5, P128
[15]  
STOUT DB, 2005, MOL IMAGING BIOL, P1
[16]  
Sundaresan G, 2003, J NUCL MED, V44, P1962
[17]  
Tai YC, 2005, J NUCL MED, V46, P455
[18]  
Townsend DW, 2004, J NUCL MED, V45, p4S
[19]   Geometric misalignment and calibration in cone-beam tomography [J].
von Smekal, L ;
Kachelriess, M ;
Stepina, E ;
Kalender, WA .
MEDICAL PHYSICS, 2004, 31 (12) :3242-3266
[20]   MRI-PET REGISTRATION WITH AUTOMATED ALGORITHM [J].
WOODS, RP ;
MAZZIOTTA, JC ;
CHERRY, SR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (04) :536-546