Linear combination of multiecho data:: Short T2 component selection

被引:32
作者
Jones, CK
Xiang, QS
Whittall, KP
MacKay, AL
机构
[1] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V5Z 1M9, Canada
[2] Univ British Columbia, Dept Radiol, Vancouver, BC V6T 1W5, Canada
关键词
MRI; T-2; relaxation; image processing; myelin water; linear combination;
D O I
10.1002/mrm.10713
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The myelin sheath, which is wrapped around the axons in the brain, can be affected by many diseases, resulting in cognitive and physical disability. Other work showed water in the myelin sheath has a T-2 approximate to 15 ms. The current standard technique to estimate the fraction of myelin water in vivo is to collect multiecho data and fit the decay curves using a nonnegative least-squares (NNLS) algorithm. A new algorithm was developed to calculate optimized coefficients which were used to linearly combine multiecho data to estimate the myelin water signal. A set of simulations showed the new technique was accurate over a broad range of myelin water signal. The myelin water fraction from brain regions in scans from five volunteers, estimated by the linear combination method, agreed with the myelin water fraction estimated by the standard technique. The strength of the new technique is that the linear combination does not assume an underlying T-2 model and is 20,000 times faster than NNLS. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:495 / 502
页数:8
相关论文
共 23 条
[11]   IN-VIVO VISUALIZATION OF MYELIN WATER IN BRAIN BY MAGNETIC-RESONANCE [J].
MACKAY, A ;
WHITTALL, K ;
ADLER, J ;
LI, D ;
PATY, D ;
GRAEB, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :673-677
[12]  
Macovski A, 1982, IEEE Trans Med Imaging, V1, P42, DOI 10.1109/TMI.1982.4307547
[13]   APPLICATION OF CONTINUOUS RELAXATION-TIME DISTRIBUTIONS TO THE FITTING OF DATA FROM MODEL SYSTEMS AND EXCISED TISSUE [J].
MENON, RS ;
ALLEN, PS .
MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (02) :214-227
[14]   PROTON RELAXATION STUDIES OF WATER COMPARTMENTALIZATION IN A MODEL NEUROLOGICAL SYSTEM [J].
MENON, RS ;
RUSINKO, MS ;
ALLEN, PS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :264-274
[15]   PRACTICAL T2 QUANTITATION FOR CLINICAL-APPLICATIONS [J].
POON, CS ;
HENKELMAN, RM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (05) :541-553
[16]   Diffusion-weighted magnetic resonance imaging of cerebral white matter development [J].
Prayer, D ;
Prayer, L .
EUROPEAN JOURNAL OF RADIOLOGY, 2003, 45 (03) :235-243
[17]   Diffusional anisotropy of T2 components in bovine optic nerve [J].
Stanisz, GJ ;
Henkelman, RM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :405-410
[18]   SPIN-SPIN RELAXATION IN EXPERIMENTAL ALLERGIC ENCEPHALOMYELITIS - ANALYSIS OF CPMG DATA USING A NONLINEAR LEAST-SQUARES METHOD AND LINEAR INVERSE-THEORY [J].
STEWART, WA ;
MACKAY, AL ;
WHITTALL, KP ;
MOORE, GRW ;
PATY, DW .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :767-775
[19]  
van Buchem MA, 2001, AM J NEURORADIOL, V22, P762
[20]   WATER COMPARTMENTS IN MYELINATED NERVE .3. PULSED NMR RESULTS [J].
VASILESCU, V ;
KATONA, E ;
SIMPLACEANU, V ;
DEMCO, D .
EXPERIENTIA, 1978, 34 (11) :1443-1444