Applications of sol-gel-derived membranes to neutral carrier-type ion sensitive field-effect transistors

被引:50
作者
Kimura, K
Sunagawa, T
Yokoyama, M
机构
[1] Chemical Process Engineering, Faculty of Engineering, Osaka University, Yamada-oka, Suita
关键词
D O I
10.1021/ac9611069
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sol-gel-derived membranes encapsulating neutral carriers, such as valinomycin and a bis(crown ether) derivative, were fabricated as novel ion-sensing membranes for neutral carrier-type ion-sensitive held-effect transistors (ISFETs). The neutral carrier-type sol-gel-derived membranes obtained with an initial diethoxydimethylsilane/tetraethoxysilane ratio of 3 gave excellent results for membrane processibility and sensitivity, response time, and selectivity in the resulting ion sensors. The sol-gel-derived ion-sensing membranes containing neutral carriers are superior in the thrombogenic property to their corresponding plasticized poly(vinyl chloride) membranes. The potassium and sodium ISFETs thus obtained were successfully applied to the ion assay in blood sera.
引用
收藏
页码:2379 / 2383
页数:5
相关论文
共 14 条
[1]  
[Anonymous], CHEM PROCESSING ADV
[2]   ALL-SOLID-STATE POLY(VINYL CHLORIDE) MEMBRANE ION-SELECTIVE ELECTRODES WITH POLY(3-OCTYLTHIOPHENE) SOLID INTERNAL CONTACT [J].
BOBACKA, J ;
MCCARRICK, M ;
LEWENSTAM, A ;
IVASKA, A .
ANALYST, 1994, 119 (09) :1985-1991
[3]   CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS - A SODIUM-ION SELECTIVE SENSOR BASED ON CALIX[4]ARENE RECEPTOR MOLECULES [J].
BRUNINK, JAJ ;
HAAK, JR ;
BOMER, JG ;
REINHOUDT, DN ;
MCKERVEY, MA ;
HARRIS, SJ .
ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) :75-80
[4]   SOL-GEL ENCAPSULATION METHODS FOR BIOSENSORS [J].
DAVE, BC ;
DUNN, B ;
VALENTINE, JS ;
ZINK, JI .
ANALYTICAL CHEMISTRY, 1994, 66 (22) :A1120-A1127
[5]  
Davies C., 1962, ION ASS
[6]   THROMBOGENIC PROPERTIES OF UNTREATED AND POLY(ETHYLENE OXIDE)-MODIFIED POLYMERIC MATRICES USEFUL FOR PREPARING INTRAARTERIAL ION-SELECTIVE ELECTRODES [J].
ESPADASTORRE, C ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1995, 67 (18) :3108-3114
[7]   DETERMINATION OF THE EQUIVALENCE POINT IN POTENTIOMETRIC TITRATIONS .2. [J].
GRAN, G .
ANALYST, 1952, 77 (920) :661-671
[8]  
JENNY HB, 1980, MIKROCHIM ACTA, V2, P309
[9]   NEUTRAL-CARRIER-TYPE ION-SENSING MEMBRANES BASED ON SOL-GEL-DERIVED GLASS [J].
KIMURA, K ;
SUNAGAWA, T ;
YOKOYAMA, M .
CHEMISTRY LETTERS, 1995, (10) :967-967
[10]   UNSYMMETRICAL CALIX[4]ARENE IONOPHORE SILICONE-RUBBER COMPOSITE MEMBRANES FOR HIGH-PERFORMANCE SODIUM ION-SENSITIVE FIELD-EFFECT TRANSISTORS [J].
KIMURA, K ;
MATSUBA, T ;
TSUJIMURA, Y ;
YOKOYAMA, M .
ANALYTICAL CHEMISTRY, 1992, 64 (21) :2508-2511