共 40 条
Prostate Cancer: Computer-aided Diagnosis with Multiparametric 3-T MR Imaging-Effect on Observer Performance
被引:110
作者:
Hambrock, Thomas
[1
]
Vos, Pieter C.
[1
]
Hulsbergen-van de Kaa, Christina A.
[1
]
Barentsz, Jelle O.
[1
]
Huisman, Henkjan J.
[1
]
机构:
[1] Radboud Univ Nijmegen, Med Ctr Nijmegen, Dept Radiol, NL-6525 GA Nijmegen, Netherlands
来源:
关键词:
CONTRAST-ENHANCED MRI;
APPARENT DIFFUSION-COEFFICIENT;
PERIPHERAL ZONE;
3;
T;
RADICAL PROSTATECTOMY;
GLEASON GRADE;
LOCALIZATION;
AGGRESSIVENESS;
COMBINATION;
PARAMETERS;
D O I:
10.1148/radiol.12111634
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
100231 [临床病理学];
100902 [航空航天医学];
摘要:
Purpose: To determine the effect of computer-aided diagnosis (CAD) on less-experienced and experienced observer performance in differentiation of benign from malignant prostate lesions at 3-T multiparametric magnetic resonance (MR) imaging. Materials and Methods: The institutional review board waived the need for informed consent. Retrospectively, 34 patients were included who had prostate cancer and had undergone multiparametric MR imaging, including T2-weighted, diffusion-weighted, and dynamic contrast material-enhanced MR imaging prior to radical prostatectomy. Six radiologists less experienced in prostate imaging and four radiologists experienced in prostate imaging were asked to characterize different regions suspicious for cancer as benign or malignant on multiparametric MR images first without and subsequently with CAD software. The effect of CAD was analyzed by using a multiple-reader, multicase, receiver operating characteristic analysis and a linear mixed-model analysis. Results: In 34 patients, 206 preannotated regions, including 67 malignant and 64 benign regions in the peripheral zone (PZ) and 19 malignant and 56 benign regions in the transition zone (TZ), were evaluated. Stand-alone CAD had an overall area under the receiver operating characteristic curve (AUC) of 0.90. For PZ and TZ lesions, the AUCs were 0.92 and 0.87, respectively. Without CAD, less-experienced observers had an overall AUC of 0.81, which significantly increased to 0.91 (P = .001) with CAD. For experienced observers, the AUC without CAD was 0.88, which increased to 0.91 (P = .17) with CAD. For PZ lesions, less-experienced observers increased their AUC from 0.86 to 0.95 (P,.001) with CAD. Experienced observers showed an increase from 0.91 to 0.93 (P = .13). For TZ lesions, less-experienced observers significantly increased their performance from 0.72 to 0.79 (P = .01) with CAD and experienced observers increased their performance from 0.81 to 0.82 (P = .42). Conclusion: Addition of CAD significantly improved the performance of less-experienced observers in distinguishing benign from malignant lesions; when less-experienced observers used CAD, they reached similar performance as experienced observers. The stand-alone performance of CAD was similar to performance of experienced observers. (C)RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12111634/-/DC1
引用
收藏
页码:521 / 530
页数:10
相关论文