Label-free detection of C-reactive protein using reflectometric interference spectroscopy-based sensing system

被引:37
作者
Choi, Hyung Woo [1 ]
Sakata, Yasuhiko [1 ]
Kurihara, Yoshikazu [1 ,2 ]
Ooya, Tooru [1 ]
Takeuchi, Toshifumi [1 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, Kobe, Hyogo 6578501, Japan
[2] KONICA MINOLTA OPTO Inc, Hino, Tokyo 1918511, Japan
关键词
Reflectometric interference spectroscopy (RIfS); C-reactive protein (CRP); Protein A; Carboxymethyl dextran (CMD); Label-free biosensing; SURFACE-PLASMON RESONANCE; THIN-FILM; IMMOBILIZATION; IMMUNOASSAY; DEXTRAN; DISEASE; DESIGN; ARRAY; ASSAY;
D O I
10.1016/j.aca.2012.03.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Reflectometric interference spectroscopy (RIfS) is a label-free, time-resolved technique, and suitable for detecting antibody-antigen interaction. This work describes a continuous flow biosensor for C-reactive protein (CRP), involving an effective immobilization method of a monoclonal antibody against CRP (anti-CRP) to achieve highly sensitive RIfS-based detection of CRP. The silicon nitride-coated silicon chip (SiN chip) for the RIfS sensing was first treated with trimethylsilylchloride (TMS), followed by UV-light irradiation to in situ generation of homogeneous silanols on the surface. Following amination by 3-aminopropyltriethoxysilane, carboxymethyldextran (CMD) was grafted, and subsequently, protein A was immobilized to create the oriented anti-CRP surface. The immobilization process of protein A and anti-CRP was monitored with the RIfS system by consecutive injections of an amine coupling reagent, protein A and anti-CRP, respectively, to confirm the progress of each step in real time. The sensitivity was enhanced when all of the processes were adopted, suggesting that the oriented immobilization of anti-CRP via protein A that was coupled with the grafted CMD on the aminated surface of TMS-treated SiN chip. The feasibility of the present sensing system was demonstrated on the detection of CRP, where the silicon-based inexpensive chips and the simple optical setup were employed. It can be applied to other target molecules in various fields of life science as a substitute of surface plasmon resonance-based expensive sensors. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 68
页数:5
相关论文
共 32 条
[11]   Competitive protein adsorption on biomaterial surface studied with reflectometric interference spectroscopy [J].
Huang, Yan ;
Lu, Xiaoying ;
Qian, Weiping ;
Tang, Zuming ;
Zhong, Yinping .
ACTA BIOMATERIALIA, 2010, 6 (06) :2083-2090
[12]   Genetically engineered elastin-protein a fusion as a universal platform for homogeneous, phase-separation immunoassay [J].
Kim, JY ;
O'Malley, S ;
Mulchandani, A ;
Chen, W .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2318-2322
[13]   Detection of C-reactive protein utilizing magnetic permeability detection based immunoassays [J].
Kriz, K ;
Ibraimi, F ;
Lu, M ;
Hansson, LO ;
Kriz, D .
ANALYTICAL CHEMISTRY, 2005, 77 (18) :5920-5924
[14]   A high sensitivity assay for the inflammatory marker C-Reactive protein employing acoustic biosensing [J].
McBride J.D. ;
Cooper M.A. .
Journal of Nanobiotechnology, 2008, 6 (1)
[15]   Method of immobilization of carboxymethyl-dextran affects resistance to tissue and cell colonization [J].
McLean, KM ;
Johnson, G ;
Chatelier, RC ;
Beumer, GJ ;
Steele, JG ;
Griesser, HJ .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2000, 18 (3-4) :221-234
[16]   Characterisation of morphology of self-assembled PEG monolayers:: a comparison of mixed and pure coatings optimised for biosensor applications [J].
Mehne, Jochen ;
Markovic, Goran ;
Proell, Florian ;
Schweizer, Nina ;
Zorn, Stefan ;
Schreiber, Frank ;
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1783-1791
[17]   SPR-based immunosensor for the CRP detection - A new method to detect a well known protein [J].
Meyer, MHF ;
Hartmann, M ;
Keusgen, M .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (10) :1987-1990
[18]   PROTEIN-A LANGMUIR-BLODGETT-FILM FOR ANTIBODY IMMOBILIZATION AND ITS USE IN OPTICAL IMMUNOSENSING [J].
OWAKU, K ;
GOTO, M ;
IKARIYAMA, Y ;
AIZAWA, M .
ANALYTICAL CHEMISTRY, 1995, 67 (09) :1613-1616
[19]   C-reactive protein: a critical update [J].
Pepys, MB ;
Hirschfield, GM .
JOURNAL OF CLINICAL INVESTIGATION, 2003, 111 (12) :1805-1812
[20]   Label-free electrochemical impedance spectroscopy biosensor for the determination of human immunoglobulin G [J].
Qi, Honglan ;
Wang, Chen ;
Cheng, Ning .
MICROCHIMICA ACTA, 2010, 170 (1-2) :33-38