Optimization and application of homogeneous liquid-liquid extraction in preconcentration of copper (II) in a ternary solvent system

被引:123
作者
Farajzadeh, Mir Ali [1 ]
Bahram, Morteza [2 ]
Zorita, Saioa [3 ]
Mehr, Behzad Ghorbani [2 ]
机构
[1] Univ Tabriz, Dept Analyt Chem, Fac Chem, Tabriz, Iran
[2] Urmia Univ, Dept Chem, Fac Sci, Orumiyeh, Iran
[3] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
关键词
Homogeneous liquid-liquid extraction; Optimization; One variable at a time; Central composite design; Atomic absorption spectrophotometry; SINGLE-DROP MICROEXTRACTION; SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; EXPERIMENTAL-DESIGN; ENVIRONMENTAL-SAMPLES; WATER SAMPLES; METAL IONS; ICP-MS; TRACE; LEAD;
D O I
10.1016/j.jhazmat.2008.05.041
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study a homogeneous liquid-liquid extraction based on the Ph-dependent phase-separation process was investigated using a ternary solvent system (water-acetic acid-chloroform) for the preconcentration of Cu2+ ions. 8-Hydroxy quinoline was used as the chelating agent prior to its extraction. Flame atomic absorption spectro photometry using acetylene-air flame was used for the quantitation of analyte after preconcentration. The effect of various experimental parameters in extraction step was investigated using two optimization methods, one variable at a time and central composite design. The experimental design was done at five levels of operating parameters. Nearly the same optimized results were obtained using both methods: sample size, 5 mL: volume of NaOH 10 M, 2 mL; chloroform volume, 300 mu L; 8-hydroxy quinoline concentration more than 0.01 M and Salt amount did not affect the extraction significantly. Under the optimum conditions the calibration graph was linear over the range 10-2000 mu g L-1. The relative standard deviation was 7.6% for six repeated determinations (C = 500 mu g L-1). Furthermore, the limit of detection (S/N = 3) and limit of quantification (S/N = 10) of the method were obtained as 1.74 and 6 mu g L-1, respectively. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1535 / 1543
页数:9
相关论文
共 45 条
[1]  
Akhond M, 2005, B KOREAN CHEM SOC, V26, P882
[2]   On-line liquid-liquid extraction system using a new phase separator for flame atomic absorption spectrometric determination of ultra-trace cadmium in natural waters [J].
Anthemidis, AN ;
Zachariadis, GA ;
Farastelis, CG ;
Stratis, JA .
TALANTA, 2004, 62 (03) :437-443
[3]   Experimental design .2. Optimization [J].
Araujo, PW ;
Brereton, RG .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (02) :63-70
[4]   Induction plasma-sprayed photocatalytically active titania coatings and their characterisation by micro-Raman spectroscopy [J].
Burlacov, I. ;
Jirkovsky, J. ;
Mueller, M. ;
Heimann, R. B. .
SURFACE & COATINGS TECHNOLOGY, 2006, 201 (1-2) :255-264
[5]   Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters [J].
Cassella, RJ ;
Magalhaes, OIB ;
Couto, MT ;
Lima, ELS ;
Neves, MAFS ;
Coutinho, FMB .
TALANTA, 2005, 67 (01) :121-128
[6]   Polymer induced multiphase generation in water/organic solvent mixtures. Strategies towards the design of triphasic and tetraphasic liquid systems [J].
da Silva, LHM ;
Loh, W .
CHEMICAL COMMUNICATIONS, 1998, (07) :787-788
[7]   DETERMINATION OF CADMIUM, LEAD AND COPPER IN WATER SAMPLES BY FLAME ATOMIC-ABSORPTION SPECTROMETRY WITH PRECONCENTRATION BY FLOW-INJECTION ONLINE SORBENT EXTRACTION [J].
FANG, ZL ;
GUO, TZ ;
WELZ, B .
TALANTA, 1991, 38 (06) :613-619
[8]   An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy [J].
Ferreira, SLC ;
Lemos, VA ;
Moreira, BC ;
Costa, ACS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 2000, 403 (1-2) :259-264
[9]  
Ghaedi M, 2005, FRESEN ENVIRON BULL, V14, P1158
[10]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640