Robust frameless stereotactic localization in extra-cranial radiotherapy

被引:12
作者
Riboldi, M
Baroni, G
Spadea, MF
Bassanini, F
Tagaste, B
Garibaldi, C
Orecchia, R
Pedotti, A
机构
[1] Univ Milan, Poliecn, Dept Bioengn, TBMLab, I-20133 Milan, Italy
[2] European Inst Oncol, Div Radiotherapy, I-20141 Milan, Italy
[3] Polo Univ HS Paolo, Inst Sci Radiol, I-20142 Milan, Italy
关键词
patient positioning; frameless stereotaxis; localization accuracy; extra-cranial radiotherapy;
D O I
10.1118/1.2181299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
In the field of extra-cranial radiotherapy, several inaccuracies can make the application of frameless stereotactic localization techniques error-prone. When optical tracking systems based on surface fiducials are used, inter- and intra-fractional uncertainties in marker three-dimensional (3D) detection may lead to inexact tumor position estimation, resulting in erroneous patient setup. This is due to the fact that external fiducials misdetection results in deformation effects that are poorly handled in a rigid-body approach. In this work, the performance of two frameless stereotactic localization algorithms for 3D tumor position reconstruction in extra-cranial radiotherapy has been specifically tested. Two strategies, unweighted versus weighted, for stereotactic tumor localization were examined by exploiting data coming from 46 patients treated for extra-cranial lesions. Measured isocenter displacements and rotations were combined to define isocentric procedures, featuring 6 degrees of freedom, for correcting patient alignment (isocentric positioning correction). The sensitivity of the algorithms to uncertainties in the 3D localization of fiducials was investigated by means of 184 numerical simulations. The performance of the implemented isocentric positioning correction was compared to conventional point-based registration. The isocentric positioning correction algorithm was tested on a clinical dataset of inter-fractional and intra-fractional setup errors, which was collected by means of an optical tracker on the same group of patients. The weighted strategy exhibited a lower sensitivity to fiducial localization errors in simulated misalignments than those of the unweighted strategy. Isocenter 3D displacements provided by the weighted strategy were consistently smaller than those featured by the unweighted strategy. The peak decrease in median and quartile values of isocenter 3D displacements were 1.4 and 2.7 mm, respectively. Concerning clinical data, the weighted strategy isocentric positioning correction provided the reduction of fiducial registration errors, featuring up to 61.7% decrease in median values (versus 46.8% for the unweighted strategy) of initial displacements. The weighted strategy proved high performance in minimizing the effects of fiducial localization errors, showing a great potential in improving patient setup. The clinical data analysis revealed that the application of a robust reconstruction algorithm may provide high-quality results in patient setup verification, by properly managing external fiducials localization errors. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1141 / 1152
页数:12
相关论文
共 30 条
[1]
Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy [J].
Baroni, G ;
Troia, A ;
Riboldi, M ;
Orecchia, R ;
Ferrigno, G ;
Pedotti, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (06) :679-688
[2]
Baroni G, 2000, Comput Aided Surg, V5, P296, DOI 10.3109/10929080009148897
[3]
Implementation and application of real-time motion analysis based on passive markers [J].
Baroni, G ;
Ferrigno, G ;
Pedotti, A .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (06) :693-703
[4]
Real-time three-dimensional motion analysis for patient positioning verification [J].
Baroni, G ;
Ferrigno, G ;
Orecchia, R ;
Pedotti, A .
RADIOTHERAPY AND ONCOLOGY, 2000, 54 (01) :21-27
[5]
Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles [J].
Della Croce, U ;
Cappozzo, A ;
Kerrigan, DC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (02) :155-161
[6]
Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[7]
A study of the effects of internal organ motion on dose escalation in conformal prostate treatments [J].
Happersett, L ;
Mageras, GS ;
Zelefsky, MJ ;
Burman, CM ;
Leibel, SA ;
Chui, C ;
Fuks, Z ;
Bull, S ;
Ling, CC ;
Kutcher, GJ .
RADIOTHERAPY AND ONCOLOGY, 2003, 66 (03) :263-270
[8]
Extracranial stereotactic radiation therapy:: Set-up accuracy of patients treated for liver metastases [J].
Herfarth, KK ;
Debus, J ;
Lohr, F ;
Bahner, ML ;
Fritz, P ;
Höss, A ;
Schlegel, W ;
Wannenmacher, MF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 46 (02) :329-335
[9]
Emergent technologies for 3-dimensional image-guided radiation delivery [J].
Jaffray, DA .
SEMINARS IN RADIATION ONCOLOGY, 2005, 15 (03) :208-216
[10]
An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments [J].
Jiang, SB ;
Pope, C ;
Al Jarrah, KM ;
Kung, JH ;
Bortfeld, T ;
Chen, GTY .
PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (12) :1773-1784