Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate

被引:65
作者
McMahon, CP
Rocchitta, G
Serra, PA
Kirwan, SM
Lowry, JP
O'Neill, RD [1 ]
机构
[1] Univ Coll Dublin, Sch Chem & Chem Biol, Dublin 4, Ireland
[2] Univ Coll Dublin, Sch Biomol & Biomed Sci, Dublin 4, Ireland
关键词
D O I
10.1021/ac0518194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors for glutamate (Glu) were fabricated from Teflon-coated Pt wire (cylinders and disks), modified with the enzyme glutamate oxidase (GluOx) and electrosynthesized polymer PPD, poly(o-phenylenediamine). The polymer/enzyme layer was deposited in two configurations: enzyme before polymer (GluOx/PPD) and enzyme after polymer (PPD/GluOx). These four biosensor designs were characterized in terms of response time, limit of detection, Michaelis-Menten parameters for Glu (J(max) and Km(Glu)), sensitivity to Glu in the linear response region, and dependence on oxygen concentration, Km(02)Analysis showed that the two polymer/enzyme configurations behaved similarly on both cylinders and disks. Although the two geometries showed different behaviors, these differences could be explained in terms of higher enzyme loading density on the disks; in many analyses, the four designs behaved like a single population with a range of GluOx loading. Enzyme loading was the key to controlling the Km(02) values of these first generation biosensors. The counterintuitive, and beneficial, behavior that biosensors with higher GluOx loading displayed a lower oxygen dependence was explained in terms of the effects of enzyme loading on the affinity of GluOx for its anionic substrate. Some differences between the properties of surface immobilized GluOx and glucose oxidase are highlighted.
引用
收藏
页码:2352 / 2359
页数:8
相关论文
共 83 条
[61]   Poly(vinylferrocene)-poly(ethylene glycol) glutamate oxidase electrode for determination of L-glutamate in commercial soy sauces [J].
P. Na Nakorn ;
M. Suphantharika ;
S. Udomsopagit ;
W. Surareungchai .
World Journal of Microbiology and Biotechnology, 2003, 19 (5) :479-485
[62]   Monitoring brain chemistry in vivo: Voltammetric techniques, sensors, and behavioral applications [J].
O'Neill, RD ;
Lowry, JP ;
Mas, M .
CRITICAL REVIEWS IN NEUROBIOLOGY, 1998, 12 (1-2) :69-127
[63]   Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate [J].
O'Neill, RD ;
Chang, SC ;
Lowry, JP ;
McNeil, CJ .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (11) :1521-1528
[64]   Improving glutamate microsensors by optimizing the composition of the redox hydrogel [J].
Oldenziel, WH ;
Westerink, BHC .
ANALYTICAL CHEMISTRY, 2005, 77 (17) :5520-5528
[65]   DETECTION OF HOMOVANILLIC-ACID INVIVO USING MICROCOMPUTER-CONTROLLED VOLTAMMETRY - SIMULTANEOUS MONITORING OF RAT MOTOR-ACTIVITY AND STRIATAL DOPAMINE RELEASE [J].
ONEILL, RD ;
FILLENZ, M .
NEUROSCIENCE, 1985, 14 (03) :753-763
[66]   THE CHEMICAL NATURE OF THE MAIN CENTRAL EXCITATORY TRANSMITTER - A CRITICAL-APPRAISAL BASED UPON RELEASE STUDIES AND SYNAPTIC VESICLE LOCALIZATION [J].
ORREGO, F ;
VILLANUEVA, S .
NEUROSCIENCE, 1993, 56 (03) :539-555
[67]   ENZYME-MODIFIED MICROELECTRODES FOR IN-VIVO NEUROCHEMICAL MEASUREMENTS [J].
PANTANO, P ;
KUHR, WG .
ELECTROANALYSIS, 1995, 7 (05) :405-416
[68]   The steady state current at a microdisk biosensor [J].
Phanthong, C ;
Somasundrum, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 558 :1-8
[69]   Detection of glutamate released by neurons with an enzyme-based microelectrode: applications and limitations [J].
Poitry, S ;
PoitryYamate, C ;
Innocent, C ;
Cosnier, S ;
Tsacopoulos, M .
ELECTROCHIMICA ACTA, 1997, 42 (20-22) :3217-3223
[70]   A two-dimensional imaging biosensor to monitor enhanced brain glutamate release stimulated by nicotine [J].
Qhobosheane, M ;
Wu, DH ;
Gu, GR ;
Tan, WH .
JOURNAL OF NEUROSCIENCE METHODS, 2004, 135 (1-2) :71-78