Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate

被引:65
作者
McMahon, CP
Rocchitta, G
Serra, PA
Kirwan, SM
Lowry, JP
O'Neill, RD [1 ]
机构
[1] Univ Coll Dublin, Sch Chem & Chem Biol, Dublin 4, Ireland
[2] Univ Coll Dublin, Sch Biomol & Biomed Sci, Dublin 4, Ireland
关键词
D O I
10.1021/ac0518194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biosensors for glutamate (Glu) were fabricated from Teflon-coated Pt wire (cylinders and disks), modified with the enzyme glutamate oxidase (GluOx) and electrosynthesized polymer PPD, poly(o-phenylenediamine). The polymer/enzyme layer was deposited in two configurations: enzyme before polymer (GluOx/PPD) and enzyme after polymer (PPD/GluOx). These four biosensor designs were characterized in terms of response time, limit of detection, Michaelis-Menten parameters for Glu (J(max) and Km(Glu)), sensitivity to Glu in the linear response region, and dependence on oxygen concentration, Km(02)Analysis showed that the two polymer/enzyme configurations behaved similarly on both cylinders and disks. Although the two geometries showed different behaviors, these differences could be explained in terms of higher enzyme loading density on the disks; in many analyses, the four designs behaved like a single population with a range of GluOx loading. Enzyme loading was the key to controlling the Km(02) values of these first generation biosensors. The counterintuitive, and beneficial, behavior that biosensors with higher GluOx loading displayed a lower oxygen dependence was explained in terms of the effects of enzyme loading on the affinity of GluOx for its anionic substrate. Some differences between the properties of surface immobilized GluOx and glucose oxidase are highlighted.
引用
收藏
页码:2352 / 2359
页数:8
相关论文
共 83 条
[21]   Pharmacological evidence for the selectivity of in vivo signals obtained with enzyme-based electrochemical sensors [J].
Cui, J ;
Kulagina, NV ;
Michael, AC .
JOURNAL OF NEUROSCIENCE METHODS, 2001, 104 (02) :183-189
[22]  
Davalos A, 2000, J Stroke Cerebrovasc Dis, V9, P2, DOI 10.1053/jscd.2000.18908
[23]   FARADAIC ELECTROCHEMISTRY AT MICRO-VOLTAMMETRIC ELECTRODES [J].
DAYTON, MA ;
BROWN, JC ;
STUTTS, KJ ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1980, 52 (06) :946-950
[24]   Characterization in vitro and in vivo of the oxygen dependence of an enzyme/polymer biosensor for monitoring brain glucose [J].
Dixon, BM ;
Lowry, JP ;
O'Neill, RD .
JOURNAL OF NEUROSCIENCE METHODS, 2002, 119 (02) :135-142
[25]   COMPARISON OF 2 FIBEROPTIC L-GLUTAMATE BIOSENSORS BASED ON THE DETECTION OF OXYGEN OR CARBON-DIOXIDE, AND THEIR APPLICATION IN COMBINATION WITH FLOW-INJECTION ANALYSIS TO THE DETERMINATION OF GLUTAMATE [J].
DREMEL, BAA ;
SCHMID, RD ;
WOLFBEIS, OS .
ANALYTICA CHIMICA ACTA, 1991, 248 (02) :351-359
[26]  
Gooding JJ, 1998, ELECTROANAL, V10, P1130, DOI 10.1002/(SICI)1521-4109(199811)10:16<1130::AID-ELAN1130>3.3.CO
[27]  
2-Y
[28]   Parameters in the design of oxygen detecting oxidase enzyme electrodes [J].
Gooding, JJ ;
Hall, EAH .
ELECTROANALYSIS, 1996, 8 (05) :407-413
[29]   DIRECT MEASUREMENT OF GLUTAMATE RELEASE IN THE BRAIN USING A DUAL ENZYME-BASED ELECTROCHEMICAL SENSOR [J].
HU, YB ;
MITCHELL, KM ;
ALBAHADILY, FN ;
MICHAELIS, EK ;
WILSON, GS .
BRAIN RESEARCH, 1994, 659 (1-2) :117-125
[30]   ELECTROCATALYSIS WITH A GLUCOSE OXIDASE-IMMOBILIZED GRAPHITE ELECTRODE [J].
IKEDA, T ;
KATASHO, I ;
KAMEI, M ;
SENDA, M .
AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1984, 48 (08) :1969-1976