The biomechanical evaluation of calcium phosphate cements for use in vertebroplasty

被引:22
作者
Hong, SJ
Park, YK
Kim, JH
Lee, SH
Ryu, KN
Park, CM
Kim, YS
机构
[1] Korea Univ, Coll Med, Guro Hosp, Dept Neurosurg, Seoul 152703, South Korea
[2] Korea Univ, Coll Med, Guro Hosp, Dept Radiol, Seoul 152703, South Korea
[3] Korea Univ, Anam Hosp, Coll Med, Dept Radiol, Seoul 152703, South Korea
[4] Korea Univ, Anam Hosp, Coll Med, Dept Orthoped Surg, Seoul 152703, South Korea
[5] Kyung Hee Univ Hosp, Coll Med, Dept Radiol, Seoul, South Korea
[6] Inje Univ, Ilsan Paik Hosp, Dept Cardiothorac Surg, Seoul, South Korea
关键词
spine; compression fracture; interventional procedure; experimental study;
D O I
10.3171/spi.2006.4.2.154
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The authors evaluate the biomechanical properties of vertebral bodies (VBs) stabilized with calcium phosphate (CaP) cements for use in vertebroplasty in comparison with polymethylmethacrylate (PMMA). Methods. In the first phase of the study, 73 VBs (T3-L2; thoracic region [T3-8] and thoracolumbar region [T9-L2]) were collected from seven fresh human cadavers. Compression tests were performed before and after vertebroplasty using PMMA (compression strength 80 MPa) and three kinds of CaP cements-CaP1 (5 MPa), CaP2 (20 MPa), and CaP3 (50 MPa). The authors compared the maximal compression loads (MCLs) and stiffness before and after vertebroplasty in each of the four cement groups. In the second phase of the study, 18 paired spinal units (PSUs) were collected from three fresh human cadavers, and the authors injected two types of cement selected from the first phase of the study into the lower level of six PSUs. They compared the MCLs of the untreated and two treated groups (there were six PSUs in each type of group) to analyze the tendency of inducing compression fractures in the upper level of the PSUs. The MCLs of the PMMA-injected vertebrae were significantly increased after vertebroplasty. The MCL levels of the CaP3-injected vertebrae and the CaP2-injected thoracolumbar vertebrae were decreased from those of untreated vertebrae without being significant. The MCLs of CaP1-injected vertebrae and CaP2-injected thoracic vertebrae were significantly decreased after vertebroplasty. The stiffness of all cement groups was decreased after vertebroplasty compared with initial stiffness, significantly so in all three thoracic CaP groups. In the second compression test with PSUs, the MCLs of the CaP2- and CaP3-injected PSUs were not significantly different from those of the untreated control PSUs. Conclusions. The CaP3-injected vertebrae restored the MCLs of human vertebrae closer to their initial levels than the PMMA-injected vertebrae did. The CaP2- and CaP3-injected PSUs showed no tendency to induce compression fractures in adjacent VBs.
引用
收藏
页码:154 / 159
页数:6
相关论文
共 25 条
[1]
Percutaneous vertebroplasty for pain relief and spinal stabilization [J].
Barr, JD ;
Barr, MS ;
Lemley, TJ ;
McCann, RM .
SPINE, 2000, 25 (08) :923-928
[2]
The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1537-1541
[3]
An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Jasper, LE ;
Deramond, H .
SPINE, 2001, 26 (14) :1542-1546
[4]
Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[5]
Belkoff SM, 2002, AM J NEURORADIOL, V23, P1647
[6]
Adjacent vertebral failure after vertebroplasty - A biomechanical investigation [J].
Berlemann, U ;
Ferguson, SJ ;
Nolte, LP ;
Hein, PF .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :748-752
[7]
Correlation of thoracic and lumbar vertebral failure loads with in situ vs. ex situ dual energy X-ray absorptiometry [J].
Bürklein, D ;
Lochmüller, EM ;
Kuhn, V ;
Grimm, J ;
Barkmann, R ;
Müller, R ;
Eckstein, F .
JOURNAL OF BIOMECHANICS, 2001, 34 (05) :579-587
[8]
Cortet B, 1999, J RHEUMATOL, V26, P2222
[9]
Percutaneous vertebroplasty: State of the art [J].
Cotten, A ;
Boutry, N ;
Cortet, B ;
Assaker, R ;
Demondion, X ;
Leblond, D ;
Chastanet, P ;
Duquesnoy, B ;
Deramond, H .
RADIOGRAPHICS, 1998, 18 (02) :311-320
[10]
Experimental vertebroplasty using osteoconductive granular material [J].
Cunin, G ;
Boissonnet, H ;
Petite, H ;
Blanchat, C ;
Guillemin, G .
SPINE, 2000, 25 (09) :1070-1076